14
Technical data
Guideline values based on our experience with normal use, sufcient lter running time and a constant cyanuric acid content between 30 – 50 mg/l.
Maximum Pool Volume
Automatic
SALT
AS 5 Automatic
SALT
AS 7
Salt content
2 g/l
3.5 g/l 2 g/l 3.5 g/l
Temperature < 28 °C 70 m
3
80 m
3
90 m3 140 m3
Temperature > 28 °C 45 m
3
55 m
3
65 m3 110 m3
Technical Data
Display 4.3" TFT colour touchscreen, 32bit Microprozessor, enhanced
graphic acceleration
Salt content 1.5 40 g/l
Production mode Auto, Auto Plus+, Constant production, Safe, Pause, Boost
Automatic cell cleaning Reverse of polarity, cycles adjustable
Flow rate electrolysis cell Horizontal installation: 4.5 m³/h – 30 m³/h; Vertical installation: 5.5 m³/h – 30 m³/h
Flow control Paddle-Flow-Switch, gas sensor in electrolysis chamber
Dimension cell holder 350 x 115 mm
Cable length electrolysis cell 2 m
Max. pressure electrolysis cell 3.5 bar
Cable lenght sensors 2.5 m
Cell material Titanium plates, coated with Ruthenium/Iridium
Range of water temperature 3 °C – 45 °C
Measurement of temperature PT1000-Sensor, PVC, BNC
Measurement of pH value Single-rod sensor, BNC
Measurement of Redox value Single-rod sensor, BNC
Measurement of Salt level Titanium electrodes for measurement of conductivity
Electrical connection 240 V~, 50/60 Hz
Electrical power consumption 160 W
Protection class controller IP 65
Weight of controller Approx. 4.3 kg
Dimension controller 325 x 210 x 120 mm (H x W x D)
15
EC Declaration of Conformity
We, BAYROL Deutschland GmbH
Robert-Koch-Str. 4
82152 Planegg/Steinkirchen
Germany
hereby declare that the product models named hereafter and distributed by us meet the requirements of the EC directive mentioned below.
Product designation: Measurement, control, and dosing system for swimming pools
Product model: Automatic
SALT
Series no.: see type label on equipment
EC directives: EC – Low Voltage Directive (2014/35/EU)
EC - Radio Equipment Directive (2014/53/EU)
EC – EMC Directive (2014/30/EU)
Harmonizing standards used: EN 60730-1:2011, EN 55022:2010, EN 55014-1:2006 + A1:2009 + A2:2011
EN 61000-3-2:2006 + A1:2009, EN 61000-3-3:2008
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
Date, manufacturer signature: 01.03.2022
Signer’s information: Lars Birckenstaedt, Managing Director BAYROL Group