For automatic dehumidification, activate the option with the MODE-Button. If
the room humidity is > set humidity + 5%, the compressor starts and the fan
runs at the set air speed. If the room humidity is < set humidity - 5%, the
compressor will stop and the fan will not run. If the room humidity is between
set humidity + 5% and set humidity - 5%, the whole unit runs in the initial
operating condition. The initial value of the set humidity is 50%.
Note: With this model, the compressor switches off when the room humidity is
less than -5% of the set humidity, the fan continues to run at the set air speed.
Continuous dehumidification mode
For continuous dehumidification, activate this option with the MODE-Button.
Then the compressor will start regardless of the relative humidity in the room,
the fan will run at the highest speed by default and the fan speed can be
adjusted.
Child lock function
Press and hold the MODE key 3 sec. to activate or deactivate the key lock.
(All buttons on the control panel are disabled when the key lock is activated).
4. APPLICATION
Dehumidification
The appliance is continuously dehumidified and the drain hose (12 mm inner
diameter) is attached to the side of the device to drain the water.
Look for the water drainage connection on the left side and pull out the water
stopper.