UPS + AVR
Uninterruptible Power System
Users Manual
Back-up Series
(BS-600/1200/1700/2000)
Replace Battery
Alarm Off
Charging
Buck
Boost
BATTERY LEVEL
SPECIAL STATUS
NORMAL
BACK UP
LOW BATT.
OVER LOAD

Questions and Answers

  • A
    Amber GarciaAug 10, 2025
    Why does my Beam Tech BS-600 beep continuously and show a red LED?
    • S
      Samuel FloresAug 11, 2025
      If your Beam Tech UPS is emitting a continuous beep and the status LED is red, it indicates the UPS is overloaded. To resolve this, turn off the UPS and unplug some of the connected devices to reduce the load.
  • M
    Mackenzie OlsenAug 17, 2025
    Why doesn't my Beam Tech BS-600 provide the expected runtime?
    • P
      Paul McdanielAug 17, 2025
      If your Beam Tech UPS doesn't provide the expected runtime, it could be due to excessive loads connected to the UPS or a weak battery. Disconnect the devices from the UPS, leave the UPS plugged in for 10 hours to charge. Test it again, and if the runtime is still not as expected, the battery likely needs replacing.
  • J
    Jason WolfeAug 22, 2025
    What to do if my Beam Tech BS-600 has no output when a blackout happens?
    • A
      Andrew FaulknerAug 22, 2025
      If your Beam Tech UPS has no output during a blackout, the cause may be a dead battery. In this case, replace the battery. If this doesn't solve the problem, call for service.
  • N
    Nancy StanleyAug 29, 2025
    How to fix a Beam Tech UPS button that doesn’t work?
    • K
      Katherine RichardsAug 29, 2025
      If the button on the front panel of your Beam Tech UPS doesn’t work, the CPU inside the UPS might not be running correctly. Try resetting the UPS by pushing the button for 6 seconds. If this doesn't work, unplug the line cord and all loads from the UPS, and call for service.
  • W
    wedwardsSep 3, 2025
    What to do if my Beam Tech BS-600 UPS has no reaction when plugged into AC?
    • A
      Alice ShannonSep 3, 2025
      If your Beam Tech UPS has no reaction while AC is connected, check the line cord plug to ensure it is properly connected. Also, inspect the fuse on the rear panel (inside the drawer of inlet) and replace it if it's blown. Finally, test the wall socket with a table lamp to ensure it is working.