11
a) Delete the end limits individually
Deleting the end limits using the setting controls
1. Press the reset button (1)
2. Additionally press and hold the
downward button (2).
3. Now release the reset button (1),
but keep the downward button (2)
pressed.
4. Additionally press the reset button
(1) again.
The tubular drive makes a “clack-
clack” sound to conrm.
The nal position has been deleted.
b) Deleting both nal positions
Move the canopy to the nal position
which is to be deleted.
Move the canopy to a position be-
tween both nal positions.
1. Press the reset button (1)
2. Additionally press and hold the
downward button (2).
3. Now release the reset button (1),
but keep the downward button (2)
pressed.
4. Additionally press the reset button
(1) again.
The tubular drive makes a “clack-
clack” sound to conrm.
Both nal positions have been deleted.