For your safety
12 ─── Version: 2.1AS2000
During operation
Do not work on live electrical parts
Do not open the motor while it is live. Ensure that the protective con-
ductor is properly connected. Never disconnect electrical connec-
tions while they are live. Do not work on the motor until the voltage
has dropped below 48V. Disconnect all components from the mains
and secure against reconnection.
Do not touch hot surfaces
Check cooling of the surfaces with a thermometer. Do not touch the
housing during and after operation. Allow the motor to cool down for
at least 15 minutes after switching off.
Avoid overheating
Operate the motor according to the technical specifications. Please
refer to chapter: "Technical data", [Page16]. Ensure sufficient
cooling and switch off the motor immediately if the temperature is
too high.
Do not touch rotating components
Do not touch rotating parts while the motor is in operation. Ensure
that all parts / components on the machine / plant are firmly seated.
After operation
Before working on components, make sure that they are de-en-
ergized
Carry out a voltage test and check all safety-relevant devices for
functionality. Secure the working environment and the control cabi-
net against inadvertent power-up. See chapter: "Decommissioning",
[Page57].