EasyManua.ls Logo

Bedford W713B Series - User Manual

Bedford W713B Series
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
W713B Series
Intelligent Controller
for Water Pump
User Manual
GUANGZHOU BEDFORD ELECTRIC EQUIPMENT CO.,LTD.
V1.0.0

Table of Contents

Questions and Answers

  • W
    webstercathyAug 7, 2025
    What to do if my Bedford Controller is full-frequency running?
    • C
      Christine Wilson DDSAug 8, 2025
      If your Bedford Controller is running at full frequency, it could be due to several reasons. First, check the transducer and wiring to ensure you haven't lost pressure feedback. Second, make sure parameter b05.02 is not set to 1. Finally, ensure that S2-Com is open.
  • S
    Shannon LaraAug 18, 2025
    Why does my Bedford W713B Controller display a pressure error?
    • G
      Gavin HutchinsonAug 18, 2025
      A pressure error on your Bedford Controller might stem from a few potential issues. It could be due to a detector error, so try using a standard detector. Alternatively, incorrect parameter settings could be the cause; calibrate parameters b01.05, b01.06, b01.08, b01.11, and b01.13. Lastly, avoid using excessively long transducer wires.
  • F
    foxnathanAug 27, 2025
    How to fix can't sleep error on Bedford W713B?
    • S
      Sherry MendezAug 27, 2025
      The 'Can’t Sleep' error on your Bedford Controller can arise from several issues: * Check for outlet pipe leakage and consider adjusting parameter b04.04. * Inspect for check valve leakage. * Assess if the pressure tank is damaged and replace if needed. * Address high environment EMI by using shielded wires for the transducer, connecting the shielded layer to PE. * Ensure parameter b04.00 is set to 1.

Summary

W713 B Series Intelligent Controller for Water Pump User Manual

Preface

Safety Precautions

General Warnings and Cautions

Details essential safety warnings and cautions for safe operation and to prevent equipment damage.

Product Introduction

Features and Specifications

Outlines the controller's input/output capabilities, functional characteristics, and model specifications.

Selection and Dimensions

Provides guidance for selecting the appropriate model and details the controller's external dimensions.

Environmental Requirements

Wiring

Main Circuit Terminals Wiring

Details the wiring connections for the main power and motor terminals, including grounding requirements.

Control Circuits Terminals Wiring

Explains the connections for control signals, analog inputs, digital inputs, and communication interfaces.

Control Terminals Overall Connect

Illustrates the comprehensive wiring diagram for control terminals and system connections.

Wiring Main Circuits and Components

Details main circuit wiring, breaker selection, optional reactors, EMC filters, and ground wiring.

Operation

Keypad Description

Identifies and explains the function of each key on the controller's keypad interface.

Operation Procedure

Details the steps for operating the controller, including display content and initialization.

Parameter Setting Basics

Explains display interpretation, initialization, and the parameter setting menu structure.

Instructions of Parameters Group

Quick Debug of Parameter Setting

Application Guidance

Constant Pressure Water Supply Applications

Covers single pump and multi-pump systems for constant pressure water supply, including wiring and parameters.

Constant Differential Pressure Water Supply Applications

Details single and multi-pump systems for constant differential pressure, including system introduction, wiring, and parameters.

Constant Temperature Water Supply Applications

Explains single and multi-pump systems for constant temperature control, including wiring and parameters.

Constant Differential Temperature Water Supply Applications

Details single and multi-pump systems for constant differential temperature, including system introduction, wiring, and parameters.

Fault and Troubleshooting

System Running Faults

Troubleshooting guide for system running faults, including reasons and solutions.

Water Supply Running Faults

Troubleshooting guide for water supply running faults, covering various fault types and causes.

Controller Running Faults

Troubleshooting guide for controller running faults, including inverter and communication issues.

Communication Protocol

Bedford W713B Series Specifications

General IconGeneral
BrandBedford
ModelW713B Series
CategoryController
LanguageEnglish

Related product manuals