4.7 Starting the programme
PressStart/Pausebuttontostarttheprogramme.
Programmefollow-uplightshowingthestartupofthe
programmewillturnon.
Progress of programme
Progressofarunningprogrammecanbefollowedfromthe
ProgrammeFollow-upindicatorwiththelights"Running"and
"End/Cancel".
C
INFORMATIONS
Ifthemachinedoesnotpasstothespinningstep,automatic
unbalanced load detection system might have been activated due to
the unbalanced distribution of the laundry in the machine.
4.8 Loading door lock
Thereisalockingsystemontheloadingdoorofthemachine
thatpreventsopeningofthedoorincaseswhenthewater
level is unsuitable.
Ifyouwanttoopenloadingdoorwhenthemachineisinuse,
press"Start/Pause"buttontopausethemachine."Door
Open"lightwillstartflashingwhenthemachineisswitched
toPausemode.Machinechecksthelevelofthewaterinside.
Ifthelevelissuitable,"DoorOpen"lightilluminatessteadily
within1-2minutesandtheloadingdoorcanbeopened.
Ifthelevelisunsuitable,"DoorOpen"lightturnsoffandthe
loadingdoorcannotbeopened.Ifyouareobligedtoopen
theloadingdoorwhenthe"DoorOpen"lightisoff,you
have to cancel the current programme; see "Cancelling the
programme".
Switching the machine to pause mode
Pressthe"Start/Pause"buttontoswitchthemachineto
pausemodewhileaprogrammeisrunning."Running"light
startsflashingontheProgrammeFollow-upindicatortoshow
thatthemachinehasbeenswitchedtothepausemode.
When the loading door is ready to be opened, "Door Open"
lightwillilluminatecontinuously.
Adding or taking out laundry
Press"Start/Pause"buttontoswitchthemachinetopause
mode.Whenthemachineisswitchedtopausemode,
"Running" light flashes. Wait until the Loading Door can be
opened. Open the Loading Door and add or take out the
laundry.
ClosetheLoadingDoor.Press"Start/Pause"buttontostart
the machine.
C
INFORMATIONS
Thedoorcanbeopenedifthewaterlevelissuitable.Dooropen
symbolflashesuntiltheloadingdoorgetsreadytobeopened.The
symbol’slightissteadywhenthedoorisreadytoopen.Youcan
open the door to add/take out laundry.
4.9 Cancelling the programme
Tocanceltheprogramme,turntheProgrammeSelectionknob
toselectanotherprogramme.Previousprogrammewillbe
cancelled."End/Cancel"lightwillflashcontinuouslytonotify
that the programme has been cancelled.
C
INFORMATIONS
Ifyoustartanewprogrammeaftercancellingthepreviousone,
thisnewprogrammewillstartwithoutdrainingthewaterinthe
machine.
Ifyoumustcertainlyopentheloadingdoorwhenthe“Door
Open”lightisoff,youneedtouse“Spin+Pump”programme.See
“Spin+Pump”
Re-spinning the laundry
Unbalanced load control system can prevent spinning
becauseofunbalancedloadoflaundryinthemachine.Ifyou
wouldliketospinagain:
Rearrangethelaundryinthemachine.SelectSpin+Pump
programmeandpress“Start/Pause"button.
4.10 End of programme
"End/Cancel"lightontheprogrammefollow-upindicatorwill
light up once the programme comes to an end; and "Door
Open" symbol flashes for 1-2 minutes until the door is ready
to open. When "Door Open" symbol is steadily illuminated, the
door can be opened.
Toturnoffthemachine,turnprogramselectionknobto"On
/Off"position.Takeoutyourlaundryandclosetheloading
door.Themachinewillbereadyforthenextrun.
4.11 Door Open
"DoorOpen"symbolisilluminatedwhenthedoorisready
toopen.Itflashesuntilthedoorgetsreadytoopen.Ifthe
"Door Open" symbol is not illuminated, do not force the door
toopen.Thesymbol'slightissteadywhenthedoorisready
to open.
4.12 Your machine is equipped
with a “Standby Mode”
Incaseofnotstartinganyprogrammeorwaitingwithout
makinganyotheroperationwhenthemachineisturnedon
byOn/Offbuttonandwhileitisinselectionsteporifnoother
operationisperformedapproximately2minutesafterthe
programme you selected has come to an end, your machine
willautomaticallyswitchtoenergysavingmode.Brightnessof
indicatorlightswilldecrease.Also,ifyourproductisequipped
withadisplayshowingtheprogrammeduration,thisdisplay
willcompletelyturnoff.IncaseofrotatingtheProgramme
Selectionknoborpressinganybutton,lightsanddisplay
willrestoretotheirpreviouscondition.Yourselectionsmade
whileexitingtheenergysavingmodemaychange.Check
the appropriateness of your selections before starting the
programme.Readjustifnecessary.Thisisnotafault.