Technical data
33
CP9xx_D00349_08_M_XXEN/02.2022
Audio
Line IN..................................................................................................................................................................... not used
Line OUT..................................................................................Output to a STEREO playback device via 3.5 mm jack plug
Cable length................................................................................................................................................................< 3 m
Device connections
Terminal block (L1; N; PE) (for CP915 and CP924 only)
Conductor sizes ....................................................................................................................................AWG 20…12
Stripping length.................................................................................................................................... 10…11 mm
rigid/flexible..........................................................................................................................................0.5…4 mm²
flexible with ferrule with/without plastic sleeve.................................................................................0.5…4 mm²
Multiple conductor, flexible with TWIN ferrule with plastic sleeve.................................................... 0.5…4 mm²
Plug-in terminal (A1/+;A2/) (11;12;14)
Conductor sizes ....................................................................................................................................AWG 24…12
Stripping length.............................................................................................................................................. 10 mm
rigid/flexible.......................................................................................................................................0.2…2.5 mm²
flexible with ferrule with/without plastic sleeve............................................................................0.25…2.5 mm²
Multiple conductor, flexible with TWIN ferrule with plastic sleeve.................................................0.5…1.5 mm²
Plug-in terminal (l1;k1;l2;k2…l12;k12) (AMB;BMB;SMB;ABMS;BBMS;SBMS)
Conductor sizes ....................................................................................................................................AWG 24…16
Stripping length.............................................................................................................................................. 10 mm
rigid/flexible.......................................................................................................................................0.2…1.5 mm²
flexible with ferrule without plastic sleeve.....................................................................................0.25…1.5 mm²
flexible with ferrule with plastic sleeve.........................................................................................0.25…0.75 mm²
For UL applications (CP907 only)
Use copper lines only.
Minimum temperature range of the cable to be connected to the plug-in terminals .............................................75 °C
Minimum temperature range of the cable to be connected to the PoE plug ............................................................80 °C
Environment/EMC
EMC...................................................................................................................................................................IEC 61326-1
Operating temperature
CP907 .................................................................................................................................................. -10…+55 °C
CP907 for UL applications...................................................................................................................-10…+50 °C
CP915/CP924........................................................................................................................................ -5…+40 °C
Operating altitude ....................................................................................................................................≤ 2000 m AMSL
Rel. humidity ..........................................................................................................................................................≤ 98 %
Classification of climatic conditions acc. to IEC 60721
Stationary use (IEC 60721-3-3) .........................................................................................................................3K22
Transport (IEC 60721-3-2) .....................................................................................................
.......................... 2K11
Long-term storage (IEC 60721-3-1)..................................................................................................................1K22
Classification of mechanical conditions acc. to IEC 60721
Stationary use (IEC 60721-3-3) CP907 only ....................................................................................................3M11
Stationary use (IEC 60721-3-3) CP915 and CP924 only .................................................................................3M10
Transport (IEC 60721-3-2) .................................................................................................................................2M4
Long-term storage (IEC 60721-3-1).................................................................................................................1M12
Other
Operating mode ................................................................................................................................ continuous operation
Mounting .................................................................................................................................................. display-oriented
Degree of protection, front............................................................................................................................................IP54
Degree of protection, front, for UL applications .......................................................................................................... IP50
Degree of protection, enclosure....................................................................................................................................IP20
Flammability class.................................................................................................................................................UL 94V-0