35
LIFT WILL NOT STAY UP
POSSIBLE CAUSE
1. Air in oil, (1,2,3)
2. Check valve leaks, (5)
3. Cylinders leak internally, (6)
4. Lowering valve leaks, (1,4,5,6)
5. Leaking ttings, (7)
REMEDY INSTRUCTION
1. Check oil level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .The oil level should be up to the ll screw in the
reservoir with the lift all the way down.
2. Oil seal damaged and cocked . . . . . . . . . . . . . . . . . . . . . . . . Replace oil seal around pump shaft.
3. Bleed cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Refer to Installation Manual.
4. Replace with new valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace with new valve.
5. Return unit for repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return unit for repair.
6. See Installation Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Consult Lift Manufacturer.
7. Check complete hydraulic system for leaks. . . . . . . . . . . . . . . Tighten all hydraulics ttings and inspects all
hoses.
OUR LIFTS ARE SHIPPED WITHOUT OIL. ADD OIL TO POWER UNIT TANK BEFORE USE.