DIAGNOSTICS
PHOT
SWC1
STOP
SWO1 SWO2
SWC2
PHOT-C
DAS
P.P. PED OPEN CLOSE
One segment of the display is linked to each input. In the event of failure it switches on
according to the following scheme.
N.C. inputs are represented by the vertical segments. N.O. inputs are represented by
the horizontal segments.
The control unit sees the message AMP1 or AMP2 in case of anti-crushing ammeter
sensor intervention.
ERROR MESSAGES
Some messages that are displayed in case of function anomalies are listed as follows:
Amp1
Obstacle error motor 1/anti-crushing Check presence of obstacles on motor 1 leaf run
Amp2
Obstacle error motor 2/anti-crushing Check presence of obstacles on motor 2 leaf run
ENC1
Error, encoder 1/detection of the obstacle
Check the correct connection of motor 1 encoder to the control unit, that
no obstacles are present along the gate stoke and the encoder operates
correctly.
ENC2
Error, encoder 2/detection of the obstacle
Check the correct connection of motor 2 encoder to the control unit, that
no obstacles are present along the gate stoke and the encoder operates
correctly.
Err1
Motor 1 circuit checking error Check motor 1 connections
Err2
Motor 2 circuit checking error Check motor 2 connections
Err3
error/fault power circuit Request technical assistance and eventually replace control unit.
Err4
PHOTA photocell checking error
Check connections, PHOT A photocell alignment or presence of obsta-
cles.
Err5
PHOTC photocell checking error
Check connections, PHOTC photocell alignment or presence of obsta-
cles.
Err6
Error edge active (during autoset) In autoset phase, the safety edge has intervened.
Err7
Error active stop (during autoset) In autoset phase, the STOP input has intervened.
Err8
Error active input (during autoset) In autoset phase a PP/Open/Close input has intervened.
thrm
Motor thermal protection intervention
Wait for motor cooling, in case reset does not take place, motor replace-
ment may be necessary
WASTE DISPOSAL
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal
and the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a
specialised company.