15
MENU FUNZIONE
Valori impostabili
ON-OFF-(Default)
MEMO
PARAMETERS
SeaU
The intervention threshold of the anti-crashing device (Encoder) during the phase at
normal speed is adjusted.*
0:Off-1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
SEAR
The intervention threshold of the anti-crashing device (Encoder) during braking is
adjusted *.
0:Off-1:minimum sensitivity - 99: maximum sensitivity
0-99-(0%)
** WARNING: AN INCORRECT SETTING OF THESE PARAMETERS MAY RESULT IN A DANGER.
COMPLY WITH REGULATIONS IN FORCE!
MENU FUNCTION
Settable values
ON-OFF-(Default)
MEMO
LOGIC
TCA
Enables or disables automatic closing
On: automatic closing enabled
Off: automatic closing disabled
(ON)
IbL
Enables or disables condominium function.
Off: condominium function disabled.
On: condominium function enabled. The step-by-step impulse or transmitter impulse
has no effect during the opening phase.
(OFF)
IbCA
The bloc of flat function is enabled or disabled.
On: the bloc of flat function is enabled. The Step-by-Step signal or the transmitter
signal has no effect during the TCA counting.
Off: the bloc of flat function is disabled.
(OFF)
SCL
Enables or disables rapid closing
On: rapid closing enabled. With the gate open or in the opening phase the intervention
of the photocell causes automatic closing after 3 s. Active only with TCA:ON.
Off: rapid closing disabled.
(OFF)
Sld
Enables or disables slowing.
On: Slowing active.
Off: Slowing excluded.
(OFF)
PP
Selects the operating mode of the ”Step by step button” and of the transmitter.
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
(OFF)
PRE
Enables or disables pre-blinking.
On: Pre-blinking enabled. Blinking is activated 3s before the motor starts.
Off: Pre-blinking disabled.
(OFF)
HAM
Enables or disables the inversion stroke function
On: Function enabled. Before each opening or closing manoeuvre the control unit
orders a manoeuvre of 2s in the opposite direction to facilitate the release of the
electric lock.
Off: Function disabled.
(OFF)
BLC
Enables or disables the block maintaining function.
Recommended for hydraulic motors to keep the leaf resting against the mechanical
stop block.
On: Block maintaining function enabled. Every 2 hours the control unit makes a clos-
ing manoeuvre with a duration of about 3s to keep the leaf in contact.
Off: Block maintaining function disabled.
(OFF)
SPN
Enables or disables starting torque function.
On: Starting torque enabled. At the start of each manoeuvre for 2s the motor oper-
ates at maximum torque.
Off: Starting torque disabled.
(ON)
LTCA
Selects the operating mode of the blinking light during the time TCA
On: Blinking light on during TCA
Off: Blinking light off during TCA
(OFF)
CLOC
Selects the mode of the OPEN input
On: OPEN input with CLOCK function.
To be used for connection to a timer for timed opening/closing. (Contact CLOSED-
gate open, Contact open, normal operation).
(OFF)