14
4 - With the <+> or <-> button, select the function you want.
5 - Press the button <PG>, the display shows the value currently set for the function selected.
6 - With the <+> or <-> button, select the value you intend to assign to the function.
7 - Press the button <PG>, the display shows the signal “PRG” which indicates that programming has been completed.
NOTES
Pressing <-> with the display turned off means an impulse of P.P.
Simultaneously pressing <+> and <-> from inside a function menu allows you to return to the previous menu without making any
changes.
Hold down the <+> key or the <-> key to accelerate the increase/decrease of the values.
After waiting 30s the control unit quits programming mode and switches off the display.
PARAMETERS, LOGIC AND SPECIAL FUNCTIONS
The tables below describe the individual functions available in the control unit.
MENU FUNCTION
Settable values
MIN-MAX-(Default)
MEMO
PARAMETERS
TCA
Automatic closing time. Active only with logic “TCA”=ON.
At the end of the set time the control unit orders a closing manoeuvre.
1-240-(40s)
TM1
Motor 1 work time. Regulates the maximum duration of the opening and closing
manoeuvre of the motor 1.
It must be set about 4 sec. longer than the actual travel time of the automatism.
5-180-(24s)
TM2
Motor 2 work time. Regulates the maximum duration of the opening and closing
manoeuvre of the motor 2.
It must be set about 4 sec. longer than the actual travel time of the automatism.
5-180-(24s)
TPed
The operating time for partial opening (pedestrian) is adjusted on motor 1.
With ENC.: ON, the value is the opening percentage over the total stroke memorised
during self-setting.
With ENC.: OFF, the value is the opening percentage over the time preset in TM1
parameter.
1-99-(50%)
PMo1
The torque applied to motor 1 in the OPENING* phase is adjusted. 1-99-(40%)
PMC1
The torque applied to motor 1 in the CLOSING* phase is adjusted. 1-99-(40%)
PMo2
The torque applied to motor 2 in the OPENING* phase is adjusted. 1-99-(40%)
PMC2
The torque applied to motor 2 in the CLOSING* phase is adjusted. 1-99-(40%)
TDMo
Mot.2 opening delay time.
Regulates the delay time of motor 2 on opening with respect to motor 1
0-15-(2s)
TDMC
Mot.1 closing delay time
Regulates the delay time of motor 1 on closing with respect to motor 2
0-40-(3s)
TLS
TLS contact activation time.
At each manoeuvre the contact closes for the set time.
1-240-(60s)
TLOc
Electric lock activation time.
If the electric lock is not used, set the parameter at 0.
0-5-(3s)
TsM1
Motor 1 slowing time
Regulates the duration of the slowing phase of motor 1 on opening and closing.
Value is calculated as a percentage on the space covered during the complete ope-
ration.
0 = slowing time disabled.
0-99-(0%)
TsM2
Motor 2 slowing time
Regulates the duration of the slowing phase of motor 2 on opening and closing.
Value is calculated as a percentage on the space covered during the complete ope-
ration.
0 = slowing time disabled.
0-99-(0%)
Pso1
The torque applied to motor 1 during braking in the opening phase is adjusted * 1-99-(70%)
PsC1
The torque applied to motor 1 during braking in the closing phase is adjusted * 1-99-(70%)
Pso2
The torque applied to motor 2 during braking in the opening phase is adjusted * 1-99-(70%)
PsC2
The torque applied to motor 2 during braking in the closing phase is adjusted * 1-99-(70%)