22
ARC CONTROL UNIT
IMPORTANT, PLEASE READ CAREFULLY:
The radio receiver in this product is compatible only with the new ARC (Advanced Rolling Code) transmitters which, thanks to 128-bit encryption ensure
superior copy-security.
Storing new ARC transmitters is quite similar to that of normal rolling code transmitters with HCS coding
1) DESCRIPTION AND INTENDED USE
Gear motor 24Vdc for heavy-duty sliding gates up to 600 Kg for residential or industrial buildings, with built-in controller CP.B1524
We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the
Benincà products and accessories and the guide for compiling the technical file and documents required under Annex V of the Machinery Directive,
mandatory under the regulations in force..
2) SPECIFICATIONS
BULL 624 TURBO
Motor power supply
115 o 230 Vac 50/60Hz
Consumption
3 A
Thrust
12 Nm
Operating jogging
Intensive use
Protection level
IP44
Operating temperature
-20°C / +50°C
Gate max. weight
600 kg
Rack module
M4
Opening speed
25 m/min
Noise level
<70 dB
Lubrication
Grease
N° of storable TX
512 ARC
Central control
CP.B6-1024 TURBO
Weight
15,7 kg
3) PRELIMINARY CHECKS
Before proceeding with installation, check the following:
- The structure (gate, pillar, guide rail) must be sturdy and stable.
- The guide rail and its wheels must be suitably sized and maintained to avoid excess friction during gate sliding.
- If available, check the CE declaration of conformity of the gate and perform the risk analysis according to the machinery directive.
- Check that the gate travel during opening/ closing is limited by sturdy mechanical stops.
QUICK PROGRAMMING
NOTE: Quick programming conditions:
- Receiver memory with less than 99 stored transmitters
- Autoset never run previously.
- Only valid with ARC (Advanced Rolling Code) transmitters
If you make a mistake during the quick programming procedure, you can disconnect the power supply and restart the procedure.
Quick programming steps
1 - Unlock the gate manually, put it in closed position with the relative end stop enabled, and lock the gate.
2 - Supply mains voltage.
3 - The flashing light turns on (make sure it is connected).
4 - The system starts saving the transmitters automatically and the control unit is put on hold, waiting for a transmitter.
To skip the quick programming step and proceed with manual programming press + and - (ESC) simultaneously.
5 - On display starts flashing the message TX00.
6 - Press the hidden key of the transmitter to be saved.
7 - PUSH appears on the display.
8 - Press the key you want to associate with the receiver.
9 - TX01 appears on the display (if the second transmitter TX02 is present).
10 - Repeat steps 6 and 7 for the subsequent transmitters to store, up to 99, checking the increase on the display (example TX15).
11 - To go to the next autoset step, press the key of a previously memorised transmitter until AUTO appears on the display.
12 - The message AUTO appears on display and the gate automatically performs 3 manoeuvres by calculating the optimal opera-
ting parameters. If the autoset operation has been completed successfully, the gate stops in open position and the message OK
appears on display.
The maximum time for programming the first transmitter is 60 seconds.
If necessary, proceed with the manual setup of PARAMETERS and LOGIC, depending on the type of installation.