Condominium function (IBL)
If used in condominiums, it may be preferable that further commands given during the opening phase are ignored.
This function can result useful if many users are involved, in a way to prevent several opening commands, given at the same
time, causing the movement to stop.
1
Press the [PGM] button to access programming or if the control unit is already in the programming
menu, press [5] until the IBL function is displayed.
PMOT
IBL
2
Press the [PGM] button to enter the IBL regulation.
The display shows the current value of the IBL parameter.
ON IBL mode activated
OFF IBL mode deactivated (default)
on
off
3 Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
The control unit goes back to the IBL menu. To exit programming, press the [PGM] and [5] buttons
at the same time or, alternatively, remove the power supply or wait 60 seconds.
PGM+5
Selection of photocells functioning (PHCL)
It is possible to select the functioning mode of the photocells connected to the PHOT input. Normally, the photocells are active
only in the closing phase, to allow the access of the vehicle even when the gate is not completely open. If this intervention is also
desired in the opening phase, modify the parameter as follows:
1
Press the [PGM] button to access programming or if the control unit is already in the programming
menu, press [5] until the PHCL menu is displayed.
PMOT
PHCL
2
Press the [PGM] button to enter the PHCL regulation.
The display shows the current value of the PHCL parameter.
Use the [5] key to select one of these values:
ON Photocells active in the opening and closing phase
OFF Photocells only active in the closure phase (default)
on
off
3 Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
The control unit goes back to the PHCL menu. To exit programming, press the [PGM] and [5] but-
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
PGM+5
Selection of direction of rotation of the motor (MINV)
The sliding gates can open by sliding to the right or to the left, as indicated in Figure.
SX
OPEN
OPEN
DX
The direction of rotation may have to be inverted according to the position of the motor.
1
Press the [PGM] button to access programming or if the control unit is already in the programming
menu, press [5] until the MINV menu is displayed.
PMOT
MINV
2
Press the [PGM] button to enter the MINV regulation.
The display shows the current value of the MINV parameter.
Use the [5] key to select one of these values:
C__O Motor with opening to the right
O__C Motor with left opening - default setting-
o--c
c--o
3 Confirm the desired value using the [PGM] key, the display shows PRG.
PRG
4
The control unit goes back to the MINV menu. To exit programming, press the [PGM] and [5] but-
tons at the same time or, alternatively, remove the power supply or wait 60 seconds.
PGM+5