47
Calibration Procedure
(A) Auto Calibration (OB, AGC/WBMeshut26Meshut 80) & Infinite Focus Calibration
1. Insert the battery into the camera. Press “Playback + Tele + Set(OK)” buttons to access the auto test
mode.
2. The LCD shows the “OB CLBT” message (Fig. 1). Put the camera in front of light source box and
make sure the camera is close to light source box tightly or can shoot the black subject.
3. Press “OK/Set” button to test automatically. . When the dialogue box showed “OK” (Fig. 2), it has
passed the test. If show “NG”, it means have not passed.
4. Press the “Playback” button to back the main menu and select the AGC/WB.
5. The display shows the “AGC/WB” message (Fig. 3). Put the camera in front of the light source box
and set it to LV10.
6. Press “OK/Set” button to run auto test.
7. When LCD shows ”OK” (Fig. 4), it has passed the test. If show “NG”, it has not passed.