Reglerneustart trotz guter Versorgungs spannung.
Prüfen Sie korrekte Erdung und externe Störsignale.
Nach Wiederkehr der Netzspannung wurde der Pro-
grammlauf automatisch forgesetzt. Kriterien werden
in der Konfiguration eingestellt.
Trotz Wiederkehr der Netzspannung wurde das Pro-
gramm nicht fortgesetzt: 1=durch Kon gu ration ver-
boten, 2=DO inaktiv, 3=Maxi malzeit überschritten,
4=Temperaturabfall zu groß
Brennvorgang wegen zu hoher Umgebungstemper-
tatur aus Sicherheitsgründen beendet (Temperatur
konfigurierbar).
Heizleistung des Ofens für unzureichend befunden
(SmartCheck). Bewertung über das erlernte Auf-
heizverhalten bei neuem Ofen oder Echtstrom/span-
nungsmessung (PM3 Modul in IO-Box).
B6: Autotune (Selbstoptimierungszyklus) aktiv. B7:
Autotune abgebrochen, weil während des Vorgangs
ein Regelkanal in Fehlerzustand gegangen ist. Daher
sind die ermittelten Parameter verwerfen.
B8: Autotune wurde zu Ende geführt, die ermittelten
Parameter wurden nach Evaluierung jedoch als nicht
geeignet befunden. B9: .. Parameter als reliabel be-
wertet und in die Konfiguration übernommen.
Internes technisches Problem: Mess-Signalverstärker
defekt. Wenden sie sich an den Kundendienst.
Internes technisches Problem: Mess-Signalverstärker
ungenau. Wenden sie sich an den Kundendienst.
Die IO-Box hat ein Problem gemeldet, siehe weitere
Angaben für Details (X.Y -> IO-Box X Modul Y).
Fehler USB-Operation: 1: Falscher Schlüssel
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
ERR
Controller restarts despite good supply voltage.
Check correct grounding and external interference.
After return of the mains voltage, the programme
run was continued automatically. Criteria are set in
the configuration.
Despite the return of the mains voltage, the program
was not continued because 1 = prohibited by confi-
guration, 2 = check DO was inactive, 3 = maximum
time exceeded, 4 = temperature drop too high
Firing process terminated due to high ambient tem-
perature for safety reasons (temperature configurab-
le).
Heating of kiln considered too weak (SmartCheck).
Compared with heat up rate recorded when kiln was
new of by voltage & current true measurement (PM3
module of IO Box).
B6: Autotune (self-optimization cycle) active. B7:
Autotune aborted because a rule channel went into
error during the process. Therefore, determined pa-
rameters are discarded.
B8: Autotune was completed, but the parameters
were found to be ineligible after evaluation. B9:
... and the determined parameters were evaluated
meaningfully and adopted into the configuration.
Internal technical problem: Measuring signal ampli-
fier defective. Contact the customer support.
Internal technical problem: measurement signal
amplifier inaccurate. Contact the customer support.
The IO-Box has reported a problem, see further de-
tails for details (X.Y -> IO-Box X module Y).
Error on USB-Operation: 1: Key mismatch
ERR