Remove oil filler cap and check the engine oil level.
If oil level is below the lower level line, refill with suitable oil
to upper level line. Do not screw in the oil filler cap when
checking oil level.
Change oil if contaminated.
1. Oil capacity: (see page 15)
Recommended engine oil:
API Service “SJ”
3) GROUND (Earth)
Make sure to ground (earth) the generator.
4. OPERATION
NOTE
The generator has been shipped without engine oil. Fill with oil or it will not start.
Do not tilt the generator when adding engine oil. This could result in overfilling and
damage to the engine
1) STARTING THE ENGINE
NOTE
Before starting the engine, do not connect the electric
apparatus.
1. Open the fuel tank air vent to the “OPEN” position.
2. Turn the fuel cock lever to the “ON” position.
3. Turn the engine switch to the “ON” position
4. Turn the choke lever to the ”position. Not necessary