11
ENGLISH
SETTINGS MENU TREE STRUCTURE
Below is a list of the parameters that can be programmed; if the adjustment board does not support the relative function, the interface returns an error message:
3.21 Menu structure
Menu Parameters
Scrolling message
only if parameter P1.05 = 1
Value
Password
level
Value set
in the factory
Personalised
values
P1
SETTINGS
P1.01 LANGUAGES
0 IT
1 RO
2 FR
3 EN
4 SR
5 HR
6 ES
7 EL
8 BG
9 PL
10 SL
USER
P1.02 TIME USER
P1.03 TIME PROGRAMM NOT AVAILABLE ON THIS MODEL
P1.05 SCROLLING 0 / 1 USER
P2 COMBUSTION
P2.01 GAS TYPE 0 / 1 INSTALLER 0
P2.02 BOILER TYPE 1 / 2 / 3 / 4 SERVICE
1 (25 kW)
2 (30 kW)
3 (35 kW)
4 (40 kW)
P2.03 COMBUSTION OFFSET 0 / 1 / 2 SERVICE
P2.04 ACC CURVE CHOICE NOT AVAILABLE ON THIS MODEL
P2.06 ACC AUTO CAL 0 / 1 SERVICE 0
P3 CONFIGURATION
P3.01
HYDRAULIC
CONFIGURATION
0 / 1 / 2 / 3 / 4 INSTALLER 1
P3.02
WATER PRESSURE
TRANSDUCER
0 / 1 SERVICE 1
P3.03 AUTO FILL ENABLE 0 / 1 SERVICE 0
P3.04 BEGIN SYSTEM FILLING NOT AVAILABLE ON THIS MODEL
P3.05 AIR PURGING CYCLE 0 / 1 SERVICE 1
P3.06 MIN FAN SPEED INSTALLER
see technical data
table
P3.07 MAX FAN SPEED INSTALLER
see technical data
table
P3.09 MAX FAN SPEED HTG MIN - MAX INSTALLER
see technical data
table
P3.10 RANGE RATED MIN - MAX_CH INSTALLER
see technical data
table
P3.11 CONFIG AUX 1 0 / 1 / 2 INSTALLER 0
P3.12 EXHAUST PROBE RESET 0 / 1 INSTALLER 0
P4 HEATING
P4.01
HYST OFF HIGH TEMP
2 - 10 SERVICE 5
P4.02
HYST ON HIGH TEMP
2 - 10 SERVICE 5
P4.03
HYST OFF LOW TEMP
2 - 10 SERVICE 3
P4.04
HYST ON LOW TEMP
2 - 10 SERVICE 3
P4.05 PUMP CONTROL TYPE 0-100 INSTALLER 85
P4.08 OT CASCADE CONTROL
NOT AVAILABLE ON THIS
MODEL
P4.09 SCREED FUNCTION 0 / 1 INSTALLER 0
P4.10 ANTI CYCLE FUNCTION 0 - 20min INSTALLER 3min
P4.11 RESET CH TIMERS 0 / 1 INSTALLER 0
P4.12
MAIN ZONE ACTUATION
TYPE
0 / 1 INSTALLER 0
P4.13 MAIN ZONE ADDRESS 1 - 6 INSTALLER 3
P4.14
MAIN ZONE HYDRAULIC
CONF
0 / 1 INSTALLER 0
P4.15 MAIN ZONE TYPE 0 / 1 INSTALLER 0
P4.16 MAX CH SET
AT: MIN CH SET - 80.5
BT: MIN CH SET - 45.0
INSTALLER
80.5
P4.17 MIN CH SET
AT: 20 - MAX CH SET
BT: 20 - MAX CH SET
INSTALLER
20
P4.18 WEATHER COMP ENABLE 0 / 1 INSTALLER 0
P4.19 WEATHER COMP CURVE
1.0-3.0
AT
0.2-0,8
BT
INSTALLER 2.0