Cleaning
Step 1: Remove the front casing from the pump by squeezing the sides and
pulling it away.
Step 2: Turn the impeller housing anticlockwise to expose the impeller inside.
Step 3: Take care when handling the ceramic impeller shaft. This is not
covered by warranty. Ensure it is clean, and not cracked or broken.
Step 4: Inspect the impeller and clean if necessary. All blades should be intact
and the magnet clean, intact and not cracked or warped.
Step 1 Step 2
Step 3 Step 4
Feature Pumps - Instruction Manual - FP Pumps 2021.indd 4 28/09/2020 14:32:21