BEFOREINSTALLATION
This appliance shall only be installed by an
authorizedprofessional.
This appliance shall be installed in accordance
withthemanufacturer’sinstallationinstructions.
This appliance must be installed in accordance
withthenorms&standardsofthecountrywhere
it will be installed. The installation of this
appliance must conform to local
codes and
ordinances. In the absence of local codes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuel GasCodeANSIZ223.1
latestedition**orB149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence of local codes, with the
National
ElectricalCode,ANSI/NFPA70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, ½” I.D. is
recommended for conn ecting this appliance to
the gas supply line. Do not bend or damage the
flexibleconnectorwhenmovingthe
appliance.
This appliance must be used with the pressure
regulator provided. The regulator shall be
properlyinstalled inorder tobe accessiblewhen
theappliance isinstalled in itsfinallocation. The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”
female
pipe thread. The appropriate fitting must be
determined basedon the size of yourgas supply
line,theflexiblemetalconnectorandtheshutoff
valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manualshutoffvalveduringanypressuretesting
ofthegas
supplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
All openingand holes in the wall and floor, back
and under the appliance shall be sealed before
installationoftheappliance.
Amanualvalveshallbeinstalledin anaccessible
location in the gas
line external to the appliance
for the purpose of turning on or shutting off gas
totheappliance
totheappliance
WARNING: This appliance shall not be installed
with a ventilation system that air downward
towardtherange/rangetop/cooktop; thistypeof
ventilation system may cause ignition and
combustion problem with the
gas cooking
appliance resulting in a personal injury or
unintendedoperation.
WARNING: an air curtain or other overhead
range/rangetop/cooktop hood, which operates
by blowing a downward airflow onto a
range/rangetop/cooktop, shall not be
used/installed in conjunction with this gas
range/rangetop/cooktop.
WARNING!
Donotuseaerosolspraysinthevicinity
ofthis
appliancewhileitisinoperation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operationmay affectotherventedappliances;in
each case it shall beinsta lled in
conformity with
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
with natural gas. For use with propane LP gas
please follow the conversion procedure
described on pg. 17. A step by step conversion
procedureisalsoincludedwitheachset
ofLP gas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
to the gas a ppliance pressure regulator is 20’’
watercolumn(5kPa).
The minimum gas supply pressure for checking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressure
to
the appliance (this operating pressure is 4” w.c.
(1.00kPa)forNaturalGasand11” w.c. (2.75 kPa
forLPGas).