Technical characteristics
Displays
Appliance must be descaled.
Flashing – descaling starts.
Feed 2 cups descaling solution into the water tank.
Feed 4 cups cold water into the water tank for rinsing.
Indication that water tank is missing.
The water tank must be removed, emptied and reinserted.
Tank is empty, please fill with 0,5L of water.
Indication that steam reduction process is ongoing.
Indication that cold water is entering the boiler and hot
water is being pumped to the water tank.
The water tank must be removed, emptied and reinserted.
Please contact the Technical Assistance Service in case of the following errors:
Temperature in the PCB is too high.
Error in the pressure sensor.
Error in the oven’s temperature sensor.
Error in the boiler’s temperature sensor.
Error in the boiler’s level detectors (Boiler Heater).
Not in use (LEVEL reserved)
Boiler Over-Heating Error
PCB Temperature Overheating Error
Memory Flash Error (EEPROM emulation)
Specifications
AC Voltage ................................................................................... (see characteristics plate)
Power required ............................................................................ 2900 W
Steam power ............................................................................... 1500 W
Broiler power ............................................................................... 1200 W
Convection power ....................................................................... 1600 W
Exterior dimensions (WHD). ..................................................... 30’’x19’’x21’’ (758475542mm)
Interior dimensions (WHD). ...................................................... 16.5’’x8.3’’x15.4’’ (420210390mm)
Oven capacity. ............................................................................. 1,24 ft
3
(35lts)
Weight ........................................................................................ 138 oz (39kg)