EasyManua.ls Logo

Bestway 58614E User Manual

Bestway 58614E
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
58614E
OWNER’S MANUAL
bestwaycorp.com/support
Visit Bestway YouTube channel
WE SUGGEST NOT TO RETURN
THE PRODUCT TO THE STORE
QUESTIONS? PROBLEMS?
MISSING PARTS?
For FAQ, Manuals, Videos Or
Spare Parts, Please Visit
bestwaycorp.com/support
V
i
s
i
t
w
w
w
.
b
e
s
t
w
a
y
c
o
r
p
.
c
o
m
/
s
u
p
p
o
r
t
f
o
r
h
e
l
p

Questions and Answers:

Bestway 58614E Specifications

General IconGeneral
BrandBestway
Model58614E
CategoryWater Pump
LanguageEnglish

Summary

Important Safety Instructions

Risk of Electric Shock - Pool Occupancy

Pump must not be used while people are inside the pool to prevent electric shock.

Risk of Injury - Child Supervision

Children must be closely supervised when using the product to prevent injury.

Electrical Connection Safety

Connect to a grounding type receptacle with GFCI. Use identical replacement parts.

GFCI Testing and Malfunction

Test GFCI before use. Do not use if defective or if it trips without testing.

Electrical Safety Distances

Maintain 1.8m from electrical outlets and 1.5m from portable appliances.

Bonding Grid Warning

The pump is not designed to be bonded to the equipotential bonding grid.

Power Cord Placement

Do not bury the cord. Locate it to prevent damage from equipment.

Damaged Cord Replacement

Replace damaged cords immediately with identical parts from manufacturer or qualified personnel.

Extension Cord Prohibition

Do not use extension cords. Connect directly to a properly located outlet.

Pool Type Compatibility

This pump is only for use with storable pools, not permanently-installed pools.

General Safety Precautions

Mounting Caution

Unit must be mounted to the base per installation instructions for shock protection.

Electrical Supply Importance

Using an unmatched electrical supply is dangerous and can cause pump failure.

Electrical Work Safety

Turn off and lock circuit breaker when working with electricity to prevent shock and injury.

Grounding Plug Safety

Do not remove grounding prong or use adapter plugs. Consult an electrician for grounding questions.

General Pump Handling

Handle pump with care, avoid cord damage, and protect from sharp objects, oil, heat, and moving parts.

Pre-Use Inspection

Examine equipment before use. Report defects or missing parts to Bestway customer service.

Pump Placement

Place pump on solid, level ground with adequate ventilation, drainage, and access, away from water accumulation.

Environmental Considerations

Protect pump from extreme weather (cold, heat, sun) to maintain performance and lifespan.

Chemical Addition Warning

Do not add chemicals directly into the filter pump.

Adult Assembly

Assembly and disassembly of the product must be performed by adults only.

Swimming Pool Usage

This product is intended for use with swimming pools only.

Replacement Parts Safety

Use only identical replacement parts for servicing to ensure continued shock protection.

GFCI Protected Receptacle

Connect only to a grounding type receptacle protected by a Class A GFCI.

Electrocution Risk Warnings

Grounded Outlet Requirement

Connect only to a properly grounded outlet and do not remove the ground pin.

Damaged Cord Inspection

Inspect the power cord before use and do not use if it is damaged.

GFCI Condition

Keep the GFCI dry and off the ground.

Wet Hands and Plug

Do not touch the plug with wet hands to avoid electric shock.

Double Insulation and Parts

The unit is double insulated; use only identical replacement parts during servicing.

Manual Reading

Read the instruction manual thoroughly before using the product.

Tag Removal Prohibition

Do not remove the safety tag attached to the product.

Unauthorized Modifications

Unauthorized changes may void user's authority to operate the equipment.

FCC Interference Measures

Correct interference by reorienting antenna, increasing separation, or using a different circuit.

Filter Pump Operation

Initial Setup Steps

Open air valves, close them when water appears, test GFCI, and start the pump.

GFCI Test Procedure

Test GFCI by pressing RESET, then TEST, then RESET again to confirm functionality.

GFCI Test Warnings

Test GFCI before each use. Do not use if the test fails.

Valve Operation Warning

Never operate the pump while connection valves are closed.

Dry Hands Requirement

Ensure hands are completely dry when plugging in the filter pump.

Dry Run Prohibition

Ensure inlet and outlet are covered by water before operating to prevent dry running.

Smart Hub Connectivity

Button Functions

On/Off button controls pump; Time setting button adjusts timer.

Wi-Fi Indicator Light

LED indicates Wi-Fi connection status: connected, damaged, lost, or waiting.

Automatic Restart Feature

Pump restarts automatically at the set time the following day.

Filter Status Indicator

Indicates dirty filter or low flow rate. Follow troubleshooting to reset.

Digital Display Status

Dash indicates standby; press On/Off to access run timer.

Troubleshooting Common Issues

Error Codes and No Water Flow

Resolve 'Er' or 'no water flow' by checking water levels, valve positions, and purging air.

Filter Indicator Lights

Clean or replace filter cartridge if indicator lights up for dirty filter or low flow.

App Control Errors

Address app prompts for pump off/uncontrollable by closing prompt or visiting support.

Wi-Fi Setup Failures

Troubleshoot Wi-Fi by checking router band, signal strength, password, and interference.

Bestway Smart Hub Connection Guide

App Download and Device Connection

Download Bestway App, connect to one mobile phone, reset connection if needed.

Connection Prerequisites

Ensure mobile device is close to pump, Wi-Fi signal is strong, and correct OS/network is used.

Step 1: Wi-Fi Connection

Ensure your mobile device is connected to Wi-Fi.

Step 2: Pump Syncing

Plug in pump, press On/Off for 5s for syncing; Wi-Fi light should flash green.

Step 3: App Syncing

Open App, login/register, add device, input Wi-Fi password, and wait for connection.

Pump Maintenance and Storage

Sharing Function Disconnect

Press the button for 5 seconds to disconnect sharing until the indicator flashes.

Maintenance Safety Caution

Ensure pump is unplugged before any maintenance to avoid severe injury or death.

Filter Cartridge Maintenance

Clean filter cartridge daily. Replace every two weeks for optimal water clarity and sanitation.

Pump Storage Instructions

Unplug, remove cartridge, detach hoses, dry components, and store in a dry, safe location.

Pump Warranty Information

Visit the Bestway website for information concerning pump warranty.

Related product manuals