7
TABLE A
TECHNICAL SPECIFICATIONS
A.C. Supply 100-130 V or 198-250 V
50-60 Hz
Cooling Forced Ventilation
Frequency Range from 87.5 to 108 MHz or
from 66 to 75 MHz
Power Output Max 300 W, typ. 250 W (Note: Limit power to
250W to maintain a good level of reliability.
RF Drive Power approximately 25 W for
P out=250 W
RF Input Impedance 50 ohm
RF Output Impedance 50 ohm
I/O Connector Standard "N" Connector
Harmonic and Spurious Signal Suppression meets or exceeds FCC and CCIR regulations
Power Consumption 800 w
TABLE B
DIMENSIONAL AND ENVIRONMENTAL SPECIFICATIONS
Cabinet Dimension 122mm(4.8")H x 420mm(16.54")W
350mm(13.78")D
Panel Size 483mm(19")W x 132mm(5.2")H
Operating Temperature -10°C to 45°C
Humidity 90% Max, Non Condensing
Weight 19 Kg
The protection acts for excessive SWR, over-temperature and overdrive. It indicates the problem with
warning lights and disables the pilot exciter.