EasyManua.ls Logo

Bezzera B2013 - The coffee supplied is too cold

Bezzera B2013
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
39
MOD. BEZZERA B2013-C2013 Compact
Problem Diagnostics/Solution Advices
The flow of coffee is excessive The coffee is supplied too
quickly and the cream is lighter
than usual.
Possible causes:
1 – The grinding of coffee is too
coarse.
2 – The coffee in the filter hold- The coffee in the filter hold-The coffee in the filter hold-
er has not been pressed
enough.
3 – The dose in the filter holder
is scarce.
4 – The pressure supplied by the
pump is high (> 10 bar – 1
MPa).
In cases 1-2-3 adjust grinding
and/or dosing of coffee.
In the 4th case, a technician
must be consulted.
The coffee supplied is too cold Possible causes:
1 – The cups are cold.
2 – The filter holders are cold.
3 – The grinding of the coffee is
too thin.
4 – The machine’s water circuit
is dirty (limestone).
5 – The boiler’s pressure is low- The boiler’s pressure is low-The boiler’s pressure is low-
er than 0.8 bar (0.08 MPa)
6 – The group is cold.
In the 1st case, use the cup
warmers.
In the 2nd case, keep the fil-
ter holder assembled on the
group.
In the 3rd case, adjust the grind-
ing of the coffee.
In cases 4-5-6, call a special-
ized technician.
The coffee supplied is warm The coffee supplied is warm if
the pressure is normal, between
1 and 1.2 bar (0.1 0.12 MPa).
In this case, the pressure value
is not correct.
Call a specialized technician to
check the exhaust valve. Mean-
while, to use the machine, open
the steam tap (Fig. 01; pos 1);
the boiler’s pressure will drop to
zero, thus causing the enabling
of the resistor and the increase
of temperature. Perform this op-
eration daily when turning on
the machine.
The coffee supplied is too hot Possible causes:
1 – The boiler’s pressure is
higher than 1.3 bar (0.13
MPa).
2 – The machine is covered by
something that prevents
cooling.
3 – The machine was installed
in a position that does not
allow air circulation
In the 1st case, call a special-
ized technician.
In cases 2-3 reset the machine’s
cooling conditions.