VU001_1010_Rev000_ISTRUZ_DOSAT_3D5_MAESTRO_CLASSICAEVA_TEC
Area Elettronica
Page | 6
14. PRESS BUTTON 5 “P” AGAIN TO MOVE ON TO THE NEXT SETUP. THE
DISPLAY SHOWS Pre-brewing . PRESS BUTTON 1 ( ENABLED ) TO
ENABLE OR BUTTON 2 ( DISABLED ) TO DISABLE. IF THE PRE-BREW
FUNCTION IS ENABLED YOU NEED TO SET ITS DURATION FOR EACH
COFFEE QUANTITY. PRESS BUTTON 1 (TO INCREASE DURATION) OR
BUTTON 2 ( TO DECREASE DURATION) . PRESS BUTTON 5 “P“ TO CONFIRM.
15. PRESS BUTTON 5 “P” AGAIN TO MOVE ON TO THE NEXT SETUP. THE
DISPLAY SHOWS Probe sensitivity “. THIS FUNCTION ADJUSTS THE
SENSITIVITY OF THE LEVEL GAUGE. 3 DIFFERENT SETTINGS ARE
AVAILABLE: LOW SENSITIVITY (SOFTENED WATER) - MEDIUM SENSITIVITY (
STANDARD WATER) HIGH SENSITIVITY (MOUNTAIN WATER). PRESS
BUTTON 1 ( TO SWITCH FROM LOW TO MEDIUM TO HIGH SENSITIVITY) OR
BUTTON 2 (TO SWITCH FROM HIGH TO MEDIUM TO LOW SENSITIVITY) .
PRESS BUTTON 5 “P“ TO CONFIRM.
16. PRESS BUTTON 5 “P” AGAIN TO MOVE ON TO THE NEXT SETUP. THE
DISPLAY SHOWS Service Cycles “. THIS FUNCTION SHOWS HOW MUCH
COFFEE CAN BE DISPENSED BEFORE THE “MAINTENANCE” MESSAGE
APPEARS WITHOUT STOPPING THE MACHINE. PRESS BUTTON 1 ( NEXT )
OR BUTTON 2 ( BACK ) TO SELECT THE DIGITS. PRESS BUTTON 3 TO
CONFIRM .
PreBrewing
DISABLED
ProbeSensitivity
MID
Service Cycles
0000