VU001_1010_Rev000_ISTRUZ_DOSAT_3D5_MAESTRO_CLASSICAEVA_TEC
Area Elettronica
Page | 6
14. PRESS BUTTON 5 “P” AGAIN TO MOVE ON TO THE NEXT SETUP. THE
DISPLAY SHOWS “ Pre-brewing “ . PRESS BUTTON 1 ( ENABLED ) TO
ENABLE OR BUTTON 2 ( DISABLED ) TO DISABLE. IF THE PRE-BREW
FUNCTION IS ENABLED YOU NEED TO SET ITS DURATION FOR EACH
COFFEE QUANTITY. PRESS BUTTON 1 (TO INCREASE DURATION) OR
BUTTON 2 ( TO DECREASE DURATION) . PRESS BUTTON 5 “P“ TO CONFIRM.
15. PRESS BUTTON 5 “P” AGAIN TO MOVE ON TO THE NEXT SETUP. THE
DISPLAY SHOWS “ Probe sensitivity “. THIS FUNCTION ADJUSTS THE
SENSITIVITY OF THE LEVEL GAUGE. 3 DIFFERENT SETTINGS ARE
AVAILABLE: LOW SENSITIVITY (SOFTENED WATER) - MEDIUM SENSITIVITY (
STANDARD WATER) – HIGH SENSITIVITY (MOUNTAIN WATER). PRESS
BUTTON 1 ( TO SWITCH FROM LOW TO MEDIUM TO HIGH SENSITIVITY) OR
BUTTON 2 (TO SWITCH FROM HIGH TO MEDIUM TO LOW SENSITIVITY) .
PRESS BUTTON 5 “P“ TO CONFIRM.
16. PRESS BUTTON 5 “P” AGAIN TO MOVE ON TO THE NEXT SETUP. THE
DISPLAY SHOWS “ Service Cycles “. THIS FUNCTION SHOWS HOW MUCH
COFFEE CAN BE DISPENSED BEFORE THE “MAINTENANCE” MESSAGE
APPEARS WITHOUT STOPPING THE MACHINE. PRESS BUTTON 1 ( NEXT )
OR BUTTON 2 ( BACK ) TO SELECT THE DIGITS. PRESS BUTTON 3 TO
CONFIRM .
PreBrewing
DISABLED
ProbeSensitivity
MID
Service Cycles
0000