SETTING THE FORCE
Turn on the display (by pressing twice the “1. OK” button).
Scroll down (“2. -“ button) to “Autoset” menu.
The autoset feature will automatically let the control board learn torques required to correctly operate the gate.
WARNING:
Once “OK” button is pressed the gate will start to move, obstruction detection is disabled
during Autoset. Be sure that no obstacle is within the working range of the gate while Autoset is being
performed.
NOTE:
the Autoset must be launched from a fully closed position. Autoset run from a different position may lead
to improper control board setting.
Press “3. OK”.Thegatewillopenandcloseautomatically.Twocycleswillbeexecuted.
At the end of the second cycle the display will show “4. OK” (Autoset successful) press “OK” (if “KO” is dis-
played, the autoset failed, usually the cause of it, is a much too heavy gate).
Turn off the display.5.
COMMON SETTINGS
Parameters:
TCA: Timer to close (sec).
Normal opening speed time: Working time (sec) at full speed during opening, after this time motor will
proceed at slow down speed).
Normal closing speed time: Working time (sec) at full speed during closing, after this time motor will
proceed at slow down speed).
Slow speed: Slow down speed: 0 (25% of full speed)
WARNING!
afterchangingtheaboveparameters(exceptTCA)anAutosetisrequired.
Logics:
TCA: Auto close enabled (ON)
3 step: 3 step logic (ON)
Ibl open: Commands during opening ignored (ON).
Photoc. Open: Photocells will be ignored while the gate is opening (ON)
1 mot on: Single gate installation (ON)
Dual gate installation (OFF)
WARNING! the automation will not function properly if logic “1 mot on” is not set correctly.
CONTROL BOARD QUICK PROGRAMMING
Technical Support: 1-877-995-8155
13