EasyManua.ls Logo

BFT SUB R - Page 14

BFT SUB R
24 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 SUB-UL
D811290_04
ENGLISH
INSTALLATION MANUAL
ENGLISH
TABLE 1
Mod.
SUB EL
SUB
SUB R
SUB E
SUB ER
SUB G
SUB GR
SUB GE
SUB GER
Block Type
electric lock
hydraulic blocks
hydraulic blocks
electric lock
electric lock
hydraulic blocks
hydraulic blocks
electric lock
electric lock
Pump flow rate
l/min gal/min
N (Kg) lbf (lb)
0.4 (V0)
0.6 (V1)
0.9 (V2)
0.6 (V1)
0.9 (V2)
0.6 (V1)
0.9 (V2)
0.6 (V1)
0.9 (V2)
0.105 (V0)
0.158 (V1)
0.237 (V2)
0.158 (V1)
0.237 (V2)
0.158 (V1)
0.237 (V2)
0.158 (V1)
0.237 (V2)
Opening angle
(degrees)
130°
130°
130°
130°
130°
180°
180°
180°
180°
Max. leaf leght
(m) (ft)
3.5
1.8
1.8
2.5
2.5
1.8
1.8
2.5
2.5
11.48
5.90
5.90
8.20
8.20
5.90
5.90
8.20
8.20
Max leaf weight
8000N (~800 Kg) 1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
1798.47 lbf (~1763 lb)
8000N (~800 Kg)
8000N (~800 Kg)
8000N (~800 Kg)
8000N (~800 Kg)
8000N (~800 Kg)
8000N (~800 Kg)
8000N (~800 Kg)
8000N (~800 Kg)
Speed
(degrees/sec)
3,9°
5,4°
9°
5,4°
9°
5,4°
9°
5,4°
9°
22.2)Thegatedoesnotopen.Theactuatorvibratesbutthereisno
movement.
1) The manual release was left engaged. Reset motorised operation.
Should an electric lock be tted, check that it opens correctly after
the start command.
2) Check that the capacitor is connected to the motor drive terminals.
3) Check that the motor common (light blue wire) is properly connected.
4) Disconnect and reconnect the power supply to the system. The rst
start command must open. Should the actuator close, reverse the
respective drive connections to the actuator.
5) Help the leaf to open by hand. If the leaf opens, check if there are any
mechanical problems with the leaf or, if necessary, adjust the by-pass
valves as described in the relevant item 12. Should the checks listed
above be satisfactory, replace the actuator.
WARNINGS
Correct controller operation is only ensured when the data contai-
ned in the present manual are observed. The company is not to
beheldresponsibleforanydamageresultingfromfailureto
observe the installation standards and the instructions contained
in the present manual.
The descriptions and illustrations contained in the present manual
arenotbinding.TheCompanyreservestherighttomakeanyalte-
rationsdeemedappropriateforthetechnical,manufacturingand
commercialimprovementoftheproduct,whileleavingtheessential
productfeaturesunchanged,atanytimeandwithoutundertaking
to update the present publication.
www.metalines.com