Combination
Outdoor air
temp
Indoor air temperature ℃ DB
16 18 20 21 22 24
TC PI TC PI TC PI TC PI TC PI TC PI
℃ DB ℃ WB kW kW kW kW kW kW kW kW kW kW kW kW
120%
-19.8 -20.0 37.2 9.69 37.1 10.28 37.1 10.74 37.0 11.02 37.1 11.36 37.0 12.02
-18.8 -19.0 37.5 9.81 37.5 10.40 37.4 10.67 37.4 11.12 37.4 11.46 37.3 12.10
-16.7 -17.0 38.2 9.98 38.1 10.55 38.1 10.89 38.0 11.22 38.0 11.53 38.0 12.13
-13.7 -15.0 38.9 10.14 38.8 10.66 38.7 11.02 38.8 11.32 38.7 11.58 38.7 12.15
-11.8 -13.0 39.5 10.27 39.4 10.72 39.4 11.05 39.4 11.33 39.3 11.62 39.3 12.11
-9.8 -11.0 40.2 10.36 40.1 10.81 40.0 11.07 40.1 11.37 40.0 11.59 40.0 12.11
-9.5 -10.0 40.5 10.37 40.4 10.81 40.3 11.08 40.4 11.34 40.3 11.47 40.3 12.04
-8.5 -9.1 40.8 10.42 40.8 10.84 40.7 11.06 40.7 11.32 40.7 11.58 40.6 12.04
-7.0 -7.6 41.3 10.45 41.2 10.78 41.1 11.03 41.2 11.26 41.1 11.50 41.0 11.89
-5.0 -5.6 44.0 10.89 43.9 11.28 43.8 11.51 43.8 11.71 43.8 11.93 43.7 12.32
-3.0 -3.7 44.6 10.86 44.5 11.18 44.4 11.35 44.4 11.56 44.3 11.79 44.3 12.13
0.0 -0.7 45.6 10.73 45.5 11.01 45.4 11.28 45.4 11.33 45.3 11.53 45.3 11.84
3.0 2.2 48.4 10.94 48.2 11.20 48.2 11.33 48.1 11.49 48.1 11.65 47.1 11.62
5.0 4.1 50.8 11.18 50.7 11.43 50.7 11.54 50.5 11.70 50.5 11.85 47.1 10.91
7.0 6.0 53.4 11.41 53.4 11.65 53.2 11.75 52.4 11.61 50.7 11.17 47.1 10.27
9.0 7.9 56.1 11.64 56.0 11.86 54.1 11.34 52.4 10.92 50.7 10.50 47.1 9.67
11.0 9.8 59.0 11.84 57.5 11.63 54.1 10.67 52.4 10.28 50.7 9.89 47.1 9.12
13.0 11.8 61.1 11.72 57.5 10.91 54.1 10.01 52.4 9.66 50.7 9.30 47.1 8.57
15.0 13.7 61.1 11.04 57.5 10.28 54.1 9.45 52.4 9.11 50.7 8.77 47.1 8.10
18.0 16.8 61.1 10.43 57.5 9.73 54.1 8.98 52.4 8.63 50.7 8.31 47.1 7.68
20.0 18.5 61.1 9.88 57.5 9.29 54.1 8.59 52.4 8.23 50.7 7.92 47.1 7.31
24.0 20.5 61.1 9.40 57.5 8.91 54.1 8.28 52.4 7.89 50.7 7.60 47.1 7.01
110%
-19.8 -20.0 37.1 10.56 37.1 11.12 37.0 11.50 37.0 11.78 37.0 12.09 36.9 12.71
-18.8 -19.0 37.5 10.67 37.4 11.16 37.4 11.52 37.3 11.80 37.3 12.16 37.3 12.70
-16.7 -17.0 38.1 10.79 38.1 11.31 38.0 11.59 37.9 11.90 38.0 12.21 37.9 12.76
-13.7 -15.0 38.8
10.89 38.7 11.39 38.7 11.68 38.6 11.93 38.7 12.21 38.6 12.74
-11.8 -13.0 39.4 11.00 39.4 11.40 39.3 11.67 39.2 11.89 39.3 12.21 39.2 12.66
-9.8 -11.0 40.1 11.02 40.0 11.44 40.0 11.63 39.9 11.90 40.0 12.14 39.9 12.56
-9.5 -10.0 40.4 11.00 40.3 11.40 40.3 11.64 40.2 11.85 40.3 12.08 40.2 12.53
-8.5 -9.1 40.8 11.03 40.7 11.43 40.7 11.60 40.6 11.80 40.6 12.08 40.6 12.46
-7.0 -7.6 41.2 11.01 41.1 11.32 41.1 11.52 41.1 11.75 41.0 11.80 41.0 12.35
-5.0 -5.6 43.9 11.45 43.8 11.81 43.7 11.96 43.7 12.18 43.7 11.81 42.7 12.50
-3.0 -3.7 44.4 11.35 44.4 11.63 44.3 11.80 44.3 11.99 44.5 11.33 41.1 11.65
0.0 -0.7 45.4 11.15 45.4 11.40 45.3 11.54 45.3 11.71 46.4 11.67 43.2 11.48
3.0 2.2 48.2 11.33 48.1 11.57 48.1 11.66 48.0 11.80 46.4 11.36 43.2 10.45
5.0 4.1 50.7 11.55 50.7 11.79 49.7 11.53 48.0 11.10 46.4 10.69 43.2 9.83
7.0 6.0 53.2 11.76 52.8 11.84 49.7 10.84 48.0 10.44 46.4 10.05 43.2 9.25
9.0 7.9 56.0 11.95 52.8 11.13 49.7 10.20 48.0 9.83 46.4 9.46 43.2 8.72
11.0 9.8 56.0 11.24 52.8 10.47 49.7 9.61 48.0 9.26 46.4 8.92 43.2 8.23
13.0 11.8 56.0 10.54 52.8 9.82 49.7
9.04 48.0 8.72 46.4 8.39 43.2 7.75
15.0 13.7 56.0 9.94 52.8 9.26 49.7 8.54 48.0 8.23 46.4 7.94 43.2 7.34
18.0 16.8 56.0 9.40 52.8 8.78 49.7 7.79 48.0 7.80 46.4 7.56 43.2 6.99
20.0 18.5 56.0 8.92 52.8 8.35 49.7 7.39 48.0 7.43 46.4 7.25 43.2 6.68
24.0 20.5 56.0 8.52 52.8 7.97 49.7 7.04 48.0 7.11 46.4 6.99 43.2 6.43
GMV6 DC Inverter VRF Units Technical Sales Guide