EasyManuals Logo

BGS technic 2200 User Manual

BGS technic 2200
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
SW-Stahl und Werkzeugvertriebs GmbH Tel. +49 (0) 2191 / 46438-0
F 56 essartS resukreveL ax +49 (0) 2191 / 46438-40
ed.lhatsws@ofni :liaM-E diehcsmeR 79824-D
Instruction Manual
BGS technic KG
Bandwirkerstr. 3
42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
www.bgstechnic.com
3. Specification
The following Specification assume a one year calibration cycle and an operating temperature of 64
to 82(18 to 28)at a relative humidity of up to 80% unless otherwise noted.
3.1 AC Current (Average sensing, calibrated to rms of sine ware)
Range
Resolution Accuracy(50Hz – 60Hz)
2000mA mA ±(3% of reading +10 digits)
20mA 10 mA ±(3% of reading +10 digits)
200A 100mA ±(2.5% of reading +10 digits)
600A 1A ±(3% of reading +10 digits)
(Overload protection: 400A on all ranges)
3.2 AC Voltage(Average sensing, calibrated to rms of sine wave)
Range
Resolution Accuracy(50Hz – 500Hz)
200V 0.1V ±(1.5% of reading +4 digits)
600V 1V ±(1.5% of reading +4 digits)
Input impedance: 9M
Overload protection: 600V AC/DC on all ranges.
3.3 DC Voltage
Range
Resolution Accuracy
200V 0.1V ±(1.2% of reading +2 digits)
600V 1V ±(1.2% of reading +3 digits)
Input impedance:9M
Overload protection: 600V DC/peak AC on all ranges.
3.4 Diode Test
Test current: <2mA
Open circuit voltage: 3.2V
Overload protection: 300V DC/peak AC
Appication: Semiconductor P – N junction good or bad test
Display reading approx diode for ward, voltage value.
3.5 Continuity Test:
Buzzer sound: <75
Overload protection: 300V DC/peak AC
3.6 Resistance
Range
Resolution Accuracy
200 ±(1.5% of reading +2 digits) 0.1
200K ±(1.5% of reading +2 digits) 100
3.7 Environment
Temperature
Normal operation: 18 to 28 (64 to 82)
Usable condition: 0 to 50(32 to 122)
Storage: - 20 to 60(- 30 to 140)
Battery removed and < 80% RH
Relative Humidity: max 80%

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BGS technic 2200 and is the answer not in the manual?

BGS technic 2200 Specifications

General IconGeneral
BrandBGS technic
Model2200
CategoryMultimeter
LanguageEnglish

Related product manuals