SW-Stahl und Werkzeugvertriebs GmbH Tel. +49 (0) 2191 / 46438-0
F 56 essartS resukreveL ax +49 (0) 2191 / 46438-40
ed.lhatsws@ofni :liaM-E diehcsmeR 79824-D
Instruction Manual
BGS technic KG
Bandwirkerstr. 3
42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
mail@bgs-technic.de
www.bgstechnic.com
3. Specification
The following Specification assume a one year calibration cycle and an operating temperature of 64℉
to 82℉(18℃ to 28℃)at a relative humidity of up to 80% unless otherwise noted.
3.1 AC Current (Average sensing, calibrated to rms of sine ware)
Range
Resolution Accuracy(50Hz – 60Hz)
2000mA mA ±(3% of reading +10 digits)
20mA 10 mA ±(3% of reading +10 digits)
200A 100mA ±(2.5% of reading +10 digits)
600A 1A ±(3% of reading +10 digits)
(Overload protection: 400A on all ranges)
3.2 AC Voltage(Average sensing, calibrated to rms of sine wave)
Range
Resolution Accuracy(50Hz – 500Hz)
200V 0.1V ±(1.5% of reading +4 digits)
600V 1V ±(1.5% of reading +4 digits)
Input impedance: 9MΩ
Overload protection: 600V AC/DC on all ranges.
3.3 DC Voltage
Range
Resolution Accuracy
200V 0.1V ±(1.2% of reading +2 digits)
600V 1V ±(1.2% of reading +3 digits)
Input impedance:9MΩ
Overload protection: 600V DC/peak AC on all ranges.
3.4 Diode Test
Test current: <2mA
Open circuit voltage: ≤3.2V
Overload protection: 300V DC/peak AC
Appication: Semiconductor P – N junction good or bad test
Display reading approx diode for ward, voltage value.
3.5 Continuity Test:
Buzzer sound: <75Ω
Overload protection: 300V DC/peak AC
3.6 Resistance
Range
Resolution Accuracy
200Ω ±(1.5% of reading +2 digits) 0.1Ω
200KΩ ±(1.5% of reading +2 digits) 100Ω
3.7 Environment
Temperature
Normal operation: 18℃ to 28℃ (64℉ to 82℉)
Usable condition: 0℃ to 50℃(32℉ to 122℉)
Storage: - 20℃ to 60℃(- 30℉ to 140℉)
Battery removed and < 80% RH
Relative Humidity: max 80%