www.bgstechnic.com
3. Specification
The following Specification assume a one year calibration cycle and an operating temperature of 64
to 82(18 to 28)at a relative humidity of up to 80% unless otherwise noted.
3.1 AC Current (Average sensing, calibrated to rms of sine ware)
Range
Resolution Accuracy(50Hz – 60Hz)
2000mA mA ±(3% of reading +10 digits)
20mA 10 mA ±(3% of reading +10 digits)
200A 100mA ±(2.5% of reading +10 digits)
600A 1A ±(3% of reading +10 digits)
(Overload protection: 400A on all ranges)
3.2 AC Voltage(Average sensing, calibrated to rms of sine wave)
Range
Resolution Accuracy(50Hz – 500Hz)
200V 0.1V ±(1.5% of reading +4 digits)
600V 1V ±(1.5% of reading +4 digits)
Input impedance: 9M
Overload protection: 600V AC/DC on all ranges.
3.3 DC Voltage
Range
Resolution Accuracy
200V 0.1V ±(1.2% of reading +2 digits)
600V 1V ±(1.2% of reading +3 digits)
Input impedance:9M
Overload protection: 600V DC/peak AC on all ranges.
3.4 Diode Test
Test current: <2mA
Open circuit voltage: 3.2V
Overload protection: 300V DC/peak AC
Appication: Semiconductor P – N junction good or bad test
Display reading approx diode for ward, voltage value.
3.5 Continuity Test:
Buzzer sound: <75
Overload protection: 300V DC/peak AC
3.6 Resistance
Range
Resolution Accuracy
200 ±(1.5% of reading +2 digits) 0.1
200K ±(1.5% of reading +2 digits) 100
3.7 Environment
Temperature
Normal operation: 18 to 28 (64 to 82)
Usable condition: 0 to 50(32 to 122)
Storage: - 20 to 60(- 30 to 140)
Battery removed and < 80% RH
Relative Humidity: max 80%