Copies of the I/B. Please reproduce them without any
changes except under special instruction from Bimar
(Italy). The pages must be reproduced and folded in
order to obtain a booklet A5 (+/- 148.5 mm width x 210
mm height). When folding, make sure you keep the good
numbering when you turn the pages of the I/B. Don’t
change the page numbering. Keep the language
integrity.
8
/
21
Assembly page 8/21
Fax +32 030 9904733
This symbol show:
The minimum distance from the appliance by a person or an object must be at
least 1 meter
This symbol indicates:
The qualified staff or the service center should replace the glass when it is
damaged and broken.
This symbol show:
The device is protected against splashing water.
INSTALLATION
After removing the packaging, check that the appliance is not damaged. If in doubt, do not use but
contact a professionally qualified expert. The parts of packaging (plastic bags, polystyrene, nails, etc.)
must not be left within children’s reach since they are potential sources of danger; dispose of them in
compliance with current regulations.
• Before connecting the heater, check that the voltage stated on the information label corresponds
with that of the electric supply. If the plug on the appliance does not fit the socket, have the socket
changed with a suitable type, by a professionally qualified expert who will make sure that the
socket cable section is suitable for the power absorbed by the appliance. Generally we advise
against the use of adaptors and/or extensions but if their use is indispensable, they must comply
with current safety norms and their electric capacity (ampères) must not be less than the maximum
stated for the appliance.
• The power socket must be exclusively resistant to bad weather and destined to external use. It must
also be positioned in an accessible place so that the plug can be removed quickly in case of an
emergency.
• The appliance must be used only when fixed to
the wall: the position must be chosen in
consideration of the following points:
1. heating area maximum 3 x 3.5 m.
2. minimum distance from floor 2.75 m.
3. minimum distance from ceiling 0.5 m.
4. minimum distance from supporting wall 5cm.
5. free space at each side of at least 50 cm.
6. must NOT be positioned where collisions are
possible.
7. must NOT be positioned immediately below a
power socket.
• Place the heater far from other sources of heat, from inflammable materials (curtains, wallpaper,
etc.), from inflammable gases or explosive materials (spray cans) or other materials that become