FX12 FLUID PUMP ASSEMBLIES – TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Material in solvent cup Worn or dirty upper packings. Replace or clean upper packings as
necessary.
Pump does not stop on
the down stroke
Worn or dirty lower ball check. Replace or clean the parts as necessary.
Pump does not stop on
the
up stroke
Worn or dirty upper ball check.
Worn or dirty lower packings.
Replace or clean the parts as necessary.
Pump runs erratically Blocked material siphon kit.
Blocked inlet lter or strainer.
Low material level.
Replace or clean the siphon kit.
Replace or clean inlet lter or strainer.
Replace or rell material container.
Pump runs, with no
output
Loose connection in between
pump and siphon assembly. Stuck
lower ball.
Check that all connections are tight.
Replace or clean the parts as necessary.