iCycler iQ
Real Time PCR
Detection System
Packing List
and
Installation Guide
Catalog Number
170-8740
For Technical Service Call Your Local Bio-Rad Office or in the U.S. Call 1-800-4BIORAD (1-800-424-6723)
Question and Answer IconNeed help?

Do you have a question about the BIO RAD iCycler iQ and is the answer not in the manual?

BIO RAD iCycler iQ Specifications

General IconGeneral
TypeReal-Time PCR Detection System
Detection Channels4
Temperature Accuracy±0.5°C
Format96-well
Thermal Accuracy±0.5°C
Sample Capacity96-well
Data AcquisitionReal-time
Thermal Range0°C to 100°C
Temperature Range0°C to 100°C

Summary

System Components and Packing List

iCycler iQ Optical Module Kit Contents

Lists the components included in the iQ Optical Module retrofit kit and pre-installed items.

Installing the Optical Module

Preparing the iCycler Reaction Module for Optical Lid

Steps for removing the standard lid and installing the optical lid on the iCycler reaction module.

Mounting the Support Bracket

Instructions for attaching the support bracket to the rear of the iCycler thermal cycler.

Mounting the Optical Module to the iCycler

Procedure for attaching the Optical Module onto the iCycler's optical lid.

Connecting to the Computer

Connecting System Cables and Identifying Connectors

Details on system cabling, including optical, reaction, and iCycler module connectors.

Installing Filters

Installing and Managing Filters in the Filter Wheels

Guidance on installing, removing, and positioning filters and filter blanks in the filter wheels.

Loading Software and Firmware

Installing the iCycler iQ Software

Step-by-step instructions for installing the iCycler iQ software from the installation CD-ROM.

Upgrading iCycler Embedded Firmware

Procedure to update the iCycler's firmware for compatibility with the iQ Detector.

Adjusting the Mask

Capturing Calibration Plate Image for Mask Adjustment

Steps to capture an image of a calibration plate using iQconfig for mask alignment.

Setting the DC Offset for Optimal Image Quality

Procedure for adjusting the DC offset to ensure correct pixel intensity and image quality.

Positioning Masks Over Plate Wells

Guide to aligning mask regions over individual wells using the Mask Editor utility.

Collecting Well Factors

Preparing the Calibration Plate with Fluorescein

Instructions for preparing a calibration plate with appropriate fluorescein concentrations.

Cycling the Calibration Plate

Steps for running the prepared calibration plate through a temperature cycling protocol.

Optimizing Image Capture for Well Factors

Guidance on optimizing image capture settings for collecting well factors.