Do you have a question about the BIONIME RIGHTEST GT333 and is the answer not in the manual?
Explains the meaning of icons and symbols displayed on the meter screen.
Details important safety and handling precautions for using the blood glucose test strips.
Steps to turn on the meter and initiate its first use after installing batteries.
Instructions for replacing batteries and the subsequent setup process.
Describes the two methods for accessing the meter's setting configuration.
Guides users through setting the date, time, format, volume, and measurement units.
Explains how to turn the meter on, manually power it off, and its auto power-off feature.
Details how the meter connects via Bluetooth for data transfer and pairing with a mobile device.
Important notes and troubleshooting tips regarding Bluetooth connectivity.
Explains the automatic code detection feature of the meter for test strips.
Describes the meter's measurement range and error indications for low or high results.
Step-by-step guide on how to correctly insert a test strip into the meter.
Instructions on how to properly remove a used test strip from the meter.
Lists all necessary components and supplies for performing a blood glucose test.
Instructions for assembling and setting the depth of the lancing device.
Details on inserting the test strip and applying the blood sample correctly.
Explains how to read results, handle countdown, and safely eject used lancets.
Describes how to set meal markers to categorize test results by meal timing.
Guides on testing using palm or forearm, including necessary precautions and advice.
Explains the meter's display window and how to recognize sufficient or insufficient blood samples.
Provides guidance on understanding blood glucose readings, including "Lo" and "Hi" indicators.
Explains the importance and purpose of performing quality control tests.
Outlines the specific situations and conditions that necessitate performing a quality control test.
Lists the essential materials needed to conduct a quality control test accurately.
Detailed instructions on how to execute a quality control test using control solution.
Guidance on comparing control test results to the specified range and identifying potential issues.
Instructions on how to access and review past blood glucose test results stored in the meter's memory.
How to view 1-day, 7-day, 14-day, 30-day, 60-day, and 90-day average glucose readings.
Basic advice on keeping the meter and test strips in good condition.
Procedures for cleaning and disinfecting the blood glucose meter.
Procedures for cleaning and disinfecting the lancing device.
Explains how temperature affects meter operation and displays an error.
Details error messages related to low battery or incorrect test strip insertion.
Covers sampling errors and specific error codes (Er1-Er5) with their solutions.
Troubleshooting steps for when the blood glucose meter fails to turn on or function correctly.
Information on the mobile app for managing blood glucose data and analysis.
Lists the technical details, dimensions, power, and operating conditions of the meter.
Outlines the warranty terms and conditions for the blood glucose monitoring system.
Provides customer support contact information and explains common symbols used in the manual.
Presents reference ranges for blood glucose levels in individuals without diabetes.
Information about the manufacturers of the meter, test strips, and control solution.
| Model | RIGHTEST GT333 |
|---|---|
| Brand | BIONIME |
| Category | Blood Glucose Meter |
| Sample Type | Capillary whole blood |
| Measurement Time | 5 seconds |
| Measurement Range | 20-600 mg/dL |
| Battery Life | Approximately 1000 tests |
| Operating Temperature | 10 - 40 °C (50 - 104 °F) |
| Operating Humidity | 10-90% RH |
| Display | LCD |
| Sample Size | 0.5 μL |
| Memory Capacity | 300 results |
| Battery Type | CR2032 |
| Automatic Shut-off | 2 minutes |
| Data Port | USB |
Loading...