EasyManua.ls Logo

BIONIME GM550 User Manual

BIONIME GM550
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
USER’S MANUAL
GM550
BIONIME CORPORATION
694, Renhua Road, Dali Dist.,
Taichung City 412, Taiwan
Tel: +886 4 24951268
Fax: +886 4 24952568
http: //www.bionime.com
E-mail: info@bionime.com
101-3GM550-231
EN
BIONIME GmbH
Tramstrasse 16, 9442 Berneck
Switzerland
GM550
Blood Glucose Monitoring System
0197
Question and Answer IconNeed help?

Do you have a question about the BIONIME GM550 and is the answer not in the manual?

BIONIME GM550 Specifications

General IconGeneral
ModelGM550
CategoryBlood Glucose Meter
Measurement Time5 seconds
Operating Conditions10-40°C, 10-90% RH
Sample Size1.0 μL
Memory Capacity500 test results
Storage Conditions10-90% RH
Measurement Range10 - 600 mg/dL (0.6 - 33.3 mmol/L)
Battery Type2 x CR2032 3.0V button cell batteries

Summary

BIONIME GM550 User's Manual

Product Identification

Displays the product name, system type, and manufacturer branding.

Preface

Introduction and Purpose

Welcomes the user and explains the manual's purpose for the GM550 BGMS.

Intended Use and Compatibility

Defines the system's intended use and specifies compatible test strips and control solutions.

Package Contents

System Kit Components

Lists all items included in the Rightest™ GM550 System Kit, detailing each component.

Rightest™ GM550 Meter

Meter Components and Controls

Details the physical parts, buttons, and display of the GM550 meter.

Display Symbols and Indicators

Explains the various symbols and indicators shown on the GM550 meter display.

Precautions and Safety

General Usage Precautions

Lists essential safety guidelines, compatibility, and usage limitations for the BGMS.

Handling and Disposal Safety

Warns about small parts, water exposure, and proper battery/meter disposal.

Blood Sample Volume Requirements

Specifies the minimum blood sample volume (1.0µL) and effects of sample volume on results.

Getting Started

Meter Activation and Battery Change

Guides on how to activate the meter and replace the CR2032 batteries for power.

Setting Up Meter Time and Date

Step-by-step instructions for configuring the meter's time and date settings.

Turning Meter On/Off and Backlight

Explains manual and automatic methods for powering the meter on/off and controlling the backlight.

Performing a Blood Test

Standard Blood Test Procedure

Provides detailed, step-by-step instructions for performing a blood glucose test.

Alternative Site Testing (AST)

Guides on how to perform blood glucose tests using palm or forearm sites.

Understanding View Window and Results

Explains view window status, test progression, and interpreting 'Lo'/'Hi' readings.

Quality Control

Quality Control Test Procedure

Step-by-step instructions for conducting a quality control test using control solution.

Test Result Memory

Recalling Test Results and Averages

Instructions on how to access past test results and calculated average values.

Troubleshooting

Error Messages and Solutions

Details common error messages (Er1-Er4) and their corresponding troubleshooting steps.

Battery and Temperature Errors

Explains battery error indicators and errors related to operating temperature.

Sampling, Code, and Malfunction Issues

Guides on resolving sampling, code errors, and troubleshooting meter malfunctions.

Specifications and Performance

Technical Specifications

Lists detailed technical specifications of the GM550 meter.

Product Limitations

Outlines limitations such as altitude effects and dehydration.

Accuracy Data

Presents accuracy data comparing the GM550 meter to a lab instrument.

Support and Warranty

Customer Service Information

Provides contact information for seeking customer service.

Warranty Terms

Details the manufacturer's warranty coverage for the GM550 meter.

Main Parts

System Components Manufacturers

Lists manufacturers and compliance details for the meter, strips, and lancets.

Related product manuals