SignalHawk™
PC and Rack Mount Models
Operation Manual
Model SH-36S-PC
Model SH-36S-RM
©Copyright 2016 by Bird Technologies, Inc.
Instruction Book Part Number 920-SHPC-OPS Rev. F
SignalHawk is a trademark of Bird Electronic Corporation
ActiveSync, Microsoft, and Windows are registered trademarks
of the Microsoft Corporation
Adobe, Acrobat Reader are registered trademarks
of Adobe Systems Incorporated

Table of Contents

Other manuals for BIRD SignalHawk SH-36S-RM

Questions and Answers

  • W
    William BurkeSep 10, 2025
    What to do if my BIRD Measuring Instruments unit locks up?
    • P
      pnewmanSep 12, 2025
      If your BIRD Measuring Instruments unit ceases to operate and locks up, the system may have become unstable. Turn off the power, wait 15 seconds, and then reapply power.
  • M
    Matthew AguirreAug 23, 2025
    Why does my BIRD SignalHawk SH-36S-RM unit turn off?
    • G
      ggouldAug 23, 2025
      Your unit might turn off due to an internal error; in this case, simply turn it back on and continue. Alternatively, the unit might have shut down because the battery was too low. If this is the case, operate the unit from the AC adapter.
  • M
    Marcus HernandezAug 25, 2025
    Why does my BIRD SignalHawk SH-36S-RM Test Equipment unit operate erratically?
    • M
      Mary GrimesAug 25, 2025
      If your unit is operating erratically, the system may have become unstable. Turn off the power, wait 15 seconds, and then reapply power.
  • T
    twilsonAug 26, 2025
    What to do if my BIRD SignalHawk SH-36S-RM Test Equipment unit ceases to operate (locks up)?
    • C
      cnelsonAug 26, 2025
      If your unit ceases to operate or locks up, it might be due to an unstable system. Turn off the power, wait 15 seconds, and then reapply power.
  • H
    Heidi RiveraAug 28, 2025
    What to do if the keys do not respond on my BIRD Test Equipment?
    • J
      Jonathan HoltAug 28, 2025
      If the keys on your unit are not responding, the unit may be locked up. Try turning the unit off and then back on.
  • A
    Amy CampbellAug 29, 2025
    What to do if my BIRD Test Equipment self test fails?
    • D
      Derek ChandlerAug 29, 2025
      If the self-test fails, it indicates an error condition. Turn the unit off and then back on. If the problem persists, return the unit for service.
  • J
    Jennifer LangSep 18, 2025
    Why does my BIRD Measuring Instruments give inaccurate readings below 100 kHz?
    • T
      Tara RiveraSep 18, 2025
      If your BIRD Measuring Instruments unit gives inaccurate readings below 100 kHz, it is because the unit is not specified for use below this frequency, even though it can be set below 100 kHz for user convenience. Do not use the unit below 100 kHz.
  • R
    Ruth MorganSep 12, 2025
    Why is my BIRD Measuring Instruments unit operating erratically?
    • A
      annekeithSep 12, 2025
      If your BIRD Measuring Instruments unit operates erratically, the system may have become unstable. Turn off the power, wait 15 seconds, and then reapply power.
  • B
    burnskevinSep 8, 2025
    Why are the keys not responding on my BIRD Measuring Instruments?
    • A
      Andrew CainSep 8, 2025
      If the keys on your BIRD Measuring Instruments unit do not respond, the unit may be locked up. Turn the unit off and then back on to resolve this.
  • G
    Gregory AtkinsonSep 5, 2025
    How to fix a BIRD Measuring Instruments unit that will not power up?
    • D
      David WaltonSep 5, 2025
      If your BIRD Measuring Instrument won't power up, the AC adapter might be damaged, in which case you should replace it. Alternatively, the battery may not be fully charged or could be damaged. Allow the battery to fully charge, or replace it.

Summary

Safety Precautions

General Safety Warnings

General safety precautions for operating personnel, including warnings about live circuits and unattended servicing.

Battery Handling Precautions

Specific warnings for handling batteries, including disposal and avoiding damage.

Introduction to SignalHawk

PC SignalHawk Controls and Indicators

Diagram and description of the front panel controls and indicators for the PC model.

Spectrum Analyzer Quick Start

Step-by-step guide for basic spectrum analysis measurements.

PC SignalHawk Setup

Installing the SignalHawk Program

Instructions for installing the PC software and drivers for the SignalHawk.

Rack Mount SignalHawk Setup

Installing the SignalHawk into a Rack

Procedures for installing the Rack-Mount unit into a standard equipment rack.

Connecting via USB and Network

Steps for connecting the Rack-Mount via USB and configuring network connections.

SignalHawk Settings and Operation

Frequency and Span Settings

Configuration of frequency range, start/stop frequencies, and span.

Bandwidth and Sweep Settings

Adjusting resolution bandwidth, video bandwidth, and sweep parameters.

Amplitude and Trace Settings

Adjusting display parameters like Autoscale, Reference, Attenuation, Preamp, Offset, Units, and Trace.

Marker and Limit Functions

Using markers to analyze signals and setting limit lines for threshold detection.

SignalHawk Measurements

Spectrum Analysis Measurement

Measures power at each frequency in the sweep range.

Occupied Bandwidth Measurement

Measures frequency band bandwidth containing specified percentage of total signal power.

Channel Power Measurement

Measures total power over a frequency range, concentrated on the center frequency.

Adjacent Channel Power Measurement

Measures relative power of frequency bands adjacent to a central channel.

SignalHawk Utilities

SignalHawk PC Tool Software

Installing PC Tool Software and Drivers

Steps for installing Windows drivers and the PC Tool software.

Maintenance Procedures

Troubleshooting Guide

Common problems, their possible causes, and suggested corrections.

Product Specifications

Detailed specifications for Frequency, Amplitude, Measurements, and other features.

BIRD SignalHawk SH-36S-RM Specifications

General IconGeneral
BrandBIRD
ModelSignalHawk SH-36S-RM