EasyManua.ls Logo

Bitzer CSH6553-50Y

Bitzer CSH6553-50Y
124 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SB-170-10
Halbhermetische Kompaktschraubenverdichter
Originalbetriebsanleitung
Deutsch .................................................................................................................................................... 2
Semi-hermetic compact screw compressors
Translation of the original Operating Instructions
English...................................................................................................................................................... 41
Compresseurs à vis compacts hermétiques accessibles
Traduction des instructions de service d'origine
Français.................................................................................................................................................... 80
CSH6553..CSH6593
CSH7553 .. CSH7593
CSH8553 .. CSH8593
CSH9553 .. CSH95113
CSH10563 .. CSH10573
CSH7673 .. CSH7693
CSH8673 .. CSH8693
CSH9663 .. CSH96113
CSK6153 .. CSK6163
CSK7153 .. CSK7193
CSW6583 .. CSW6593
CSW7573 .. CSW7593
CSW8573 .. CSW8593
CSW9563 .. CSW95113
CSW10563 .. CSW10593
Dokument für Monteure
Document for installers
Document pour des monteurs

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Bitzer CSH6553-50Y and is the answer not in the manual?

Bitzer CSH6553-50Y Specifications

General IconGeneral
ModelCSH6553-50Y
Power50 hp
Power Input37 kW
Cooling TypeAir-cooled
Motor ProtectionIP54
RefrigerantR404A, R507
Motor Voltage380-415V, 50Hz
Operating Voltage400 V

Summary

Safety

Authorized Staff

Specifies requirements for personnel performing work on compressors and systems.

Residual Risks

Outlines unavoidable risks and essential safety regulations to follow.

Safety References

Provides crucial instructions to prevent hazards and avoid damage or injury.

Application Ranges

Flammable Refrigerants (A2 L)

Addresses requirements and safety for using flammable refrigerants like R1234yf.

Commissioning

Pressure Strength Check

Procedure for verifying the refrigerant circuit's resistance to pressure.

Tightness Check

Method for ensuring the refrigerant circuit has no leaks, typically using nitrogen.

Evacuation

Steps to remove air and moisture from the system to achieve a deep vacuum.

Refrigerant Charging

Guidelines for safely adding the correct refrigerant to the system.

Pre-Start Checks

Essential checks before starting the compressor, including oil level and safety devices.

Compressor Start

Procedures for initiating compressor operation, including rotation and monitoring.

Mounting

Compressor Installation

Guidance on positioning and mounting compressors within the system.

Electrical Connection

Safety Switching Devices

Function and setting of high and low pressure switches for safety.

Compressor Protection Devices

Overview of various electronic devices protecting the compressor from faults.

Operation

Maintenance

Oil Change

Detailed instructions and precautions for changing compressor oil.