EasyManuals Logo

BIXOLON SRP-332II Command Manual

BIXOLON SRP-332II
125 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
SRP-330II/332II
Rev. 1.00 BIXOLON
- 125 -
BS SO S # RS m n
Function:
Transmit maintenance counter
Code:
ASCII
BS
SO
S
#
RS
m
n
Hex
08
0E
53
23
1E
m
n
Decimal
8
14
83
35
30
m
n
Range:
m = 1, n = 99, 102, 104
Default:
None
Description:
Transmits the value of the maintenance counter specified by n.
n
Maintenance counter (Units)
Hex
Deciamal
63
99
Number of autocutter operations.(Times)
68
104
Length of paper feed.(Km)
Remarks:
Maintenance counter data is consist of [Header ~ NULL] data as shown below:
Transmitted data
Hex
Deciaml
Amount of data
Header
5FH
95
1byte
Maintrnance counter
Depends on the mainternce counter(Units)
0 10byte
NUL
00H
0
1byte
The maintenance counter values are measurements; therefore, their values will be affected by the timing of errors
and how and when the power is turned off.
When this command is transmitted, do not transmit subsequent data until the status is received.
Differences:
None

Other manuals for BIXOLON SRP-332II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BIXOLON SRP-332II and is the answer not in the manual?

BIXOLON SRP-332II Specifications

General IconGeneral
BrandBIXOLON
ModelSRP-332II
CategoryPrinter
LanguageEnglish

Related product manuals