SRP-330II/332II
Rev. 1.00 BIXOLON
- 49 -
ESC v
Function:
Transmit paper sensor status
Code:
ASCII
ESC
v
Hex
1B
76
Decimal
27
118
Range:
None
Default:
None
Description:
This command transmits a byte of data specifying the paper sensor status.
The status of paper near end and paper end sensors is sent to the host as follows:
When paper near end is detected, 0x03 is transmitted.
When paper end is detected, 0xC is transmitted.
Remarks:
The paper sensor status can be transmitted using GS r.
The near end senor is optional while paper end sensor required.
If the printer is not equipped with a near end sensor, the paper near end sensor is considered as normal condition.