ESC D
Function:
Set horizontal tab position
Code:
ASCII
ESC
D
n1...nk
NUL
Hex
1B
44
n1...nk
00
Decimal
27
68
n1...nk
0
Range:
1 ≤ n ≤ 255 , 0 ≤ k ≤ 32
Default:
n = 8, 16, 24, 32, 40,....., 232, 240, 248
Description:
This command sets the horizontal tab position.
n defines the number of columns from the beginning of the line to the horizontal tab setting.
k denotes the number of horizontal tab positions to be set.
The horizontal tab position is stored as a value of [character width x n] measured form the beginning of the line.
Remarks:
The data [n]k signifying the set position is transmitted in the ascending order and ends with a NUL code.
ESC D NUL cancels all horizontal tab positions.
Tab position is set at the value of [character width x n] from the beginning of the line.
The character width includes the space to the right of the character, and it will be twice the normal character when the
double width characters are selected.
If the data [n]k is equal to or smaller than the preceding data [n]k-1, the horizontal tab setting has been completed.
Up to 32 horizontal tabs can be set, the data exceeding this limit is processed as normal ones.
Even if the character width is changed after setting the horizontal tab positions, the horizontal tab positions remain
unchanged.