Remarks:
This command is adapted to print image data.
pL, pH specifies the number of bytes following pH using (pL + pH x 256).
Since frequent writing operation could cause the damage to the NV memory, it is recommended to write only when
being required.
While storing data by this command, the printer is in BUSY state where receiving of data is not available. Therefore, it
is not recommended to send data during this process.
The real time commands and LSB operations are not allowed during NV memory operation process.