<Function 66> GS ( L pL pH m fn kc1 kc2 (fn=66)
Code:
ASCII
GS
(
L
pL
pH
m
fn
kc1
kc2
Hex
1D
8
4C
pL
pH
m
fn
kc1
kc2
Decimal
29
40
76
pL
pH
m
fn
kc1
kc2
Range:
(pL + pH x 256) = 4 (pL=4, pH=0)
m=48
fn=66
32 ≤ kc1 ≤ 126
32 ≤ kc2 ≤ 126
Default:
None
Description:
Deletes the NV graphics data defined by the codes kc1 and kc2.
Remarks:
The graphics data is define by Function 67.
Differences:
None