<Function 070> GS ( k pL pH cn fn m (fn=70)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
Hex
1D
28
6B
03
00
30
46
m
Decimal
29
40
107
3
0
48
70
m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=70
m=0,1
Default:
m = 0
Description:
This command selects the option for PDF417.
m
Function
0
Select the standard PDF417
1
Select the simplified PDF417
Remarks:
Settings of this function affect the processing of Functions 081.
When simplified PDF417 symbol is canceled, standard PDF417 symbol is automatically selected.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None