Page #87 background image
SRP-E300/302
Ver. 1.01 BIXOLON
- 87 -
<Function 169> GS ( k pL pH cn fn n (fn=69)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
31
45
n
Decimal
29
40
107
3
0
49
69
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=49
fn=69
48≤n≤51
Default:
n = 48
Description:
This command sets the error correction level for QR Code.
n
Function
Recovery Amount (%)
48
Error Correction Level L
7
49
Error Correction Level M
15
50
Error Correction Level Q
25
51
Error Correction Level H
30
Remarks:
The setting of this command affects the processing of <Function 181>.
Reed-Solomon correction is employed to generate a series of error correction codewords.
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
Differences:
None