SRP-E300/302
Ver. 1.01 BIXOLON
<Function 180> GS ( k pL pH cn fn m d1...dk (fn=80)
4 ≤ (pL + pH x 256) ≤7092 (0 ≤ pL ≤ 255, 0 ≤ pH ≤ 27)
cn=49
fn=80
m=48
0 ≤ d ≤ 255
k = (pL + pH x 256) – 3
This command saves symbol data of the QR Code to the symbol storage area.
■ The symbol data is defined, stored to the symbol storage area by Function 180 and printed by the specification of
Function 181. The data remains reserved after completion of printing.
■ The following shows the data available for encoding of QR code.
“0” ~ “9”, “A” ~ “Z”, SP, $, %, *, +, -, ., /, :
■ The setting of this command remains effective until the following processing is performed:
• Performing Function 180
• Performing ESC @
• Performing the printer reset or power-off