EasyManuals Logo

BIXOLON SRP-E302 Command Manual

BIXOLON SRP-E302
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #94 background imageLoading...
Page #94 background image
SRP-E300/302
Ver. 1.01 BIXOLON
- 94 -
<Function 581> GS ( k pL pH cn fn m (fn=81)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
m
Hex
1D
28
6B
03
00
3D
51
m
Decimal
29
40
107
3
0
61
81
m
Range:
pL + pH x 256) = 3 (pL=3, pH=0)
cn=61
fn=81
m=48
Default:
None
Description:
This command encodes and prints DATAMATRIX symbol data saved in the storage area.
Remarks:
In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
A symbol exceeding the printing area in size can not be printed.
Printing operation is not processed under the following conditions:
There is no data. (Function 580 cannot be executed)
The number of alphanumeric characters exceeds 2334.
The number of 8bit byte characters exceeds 1558.
The number of numeric characters exceeds 3116.
DATAMATRIX uses ECC 200 symbols.
For error correction codeword, the Reed-Solomon algorithm is employed.
The following data is automatically added during the encoding process:
Position pattern
Error correction code text
Mode separator
Pad code text

Other manuals for BIXOLON SRP-E302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BIXOLON SRP-E302 and is the answer not in the manual?

BIXOLON SRP-E302 Specifications

General IconGeneral
BrandBIXOLON
ModelSRP-E302
CategoryPrinter
LanguageEnglish

Related product manuals