SRP-E300/302
Ver. 1.01 BIXOLON
- 99 -
GS :
Function:
Start/end macro definition
Code:
ASCII
GS
:
Hex
1D
3A
Decimal
29
58
Range:
None
Default:
None
Description:
This command starts or ends macro definition.
Remarks:
The printer starts macro definition during normal operation and finishes it during macro definition upon receiving this
command.
The printer performs printing during macro definition.
The macro is executed by GS ^.
The maximum number of macro data to be defined varies with respect to printer models. The data exceeding this limit
is not stored.
ESC @ does not clear the existing defined macro. The macro remains effective until the printer reset and power
cycling are executed.
Differences:
None

Other manuals for BIXOLON SRP-E302