Labeling
Operating instructions GLP
2 -- 7
6.562.98.5.01.18
2.1.11 Calling article data via the PC or EDP
If your labeler is controlled via a PC program or en EDP system, the articles will
directly be called up via one of those two. The PLU number that was called up will
be displayed via the PLU softkey!. An input of the PLU number via the keyboard
may be locked at mode level 5. The PLU softkey then appears ”crossed out”.
2.1.12 Calling article data via the scanner
If a laser scanner is connected to the labeler and relevant scanning rules are crea-
ted (see programming instructions section 2.5.14) an automatic PLU call may, in
addition to other functions, be released after reading of the scancode applied to
the package.
The PLU number read by the laser scanner is displayed above the PLU softkey.
An input of the PLU number via the keyboard may be disabled at mode level 5.
The PLU softkey then appears ”crossed out”.
How to react to a scanning error after the relevant setting is described on page
3 -- 156. Depending on this setting, the operator is then asked to rescan the code
on the package in the case of a reading error, or on change or modification of the
scanning rules (scannig is compulsory), or to enter the scancode manually (com-
pulsory input).
In the event that an error message is output on the labeler after the transmission
of the PLU number indicating that the PLU number is not created or that PLU data
is absent (e. g. texts or label data), the operator will be asked to enter a valid PLU
number manually via the keyboard (compulsory input).
2