Labeling
Operating instructions GLP
2 -- 28
6.562.98.5.01.18
2.9 Labeling with tolerance check (only for GLP with GT--CT)
2.9.1 Description
If the display and operating unit GT--CT is connected to the GLP and the weight
class--related labeling is activated in mode level 5, the labeler may also be used
to check packages for meeting the requirements of the INternational recommen-
dedation according to OIML R87, 76/211 or the Prepackaging Regulations FPV.
Depending on the requirements, the packages may be labeled according to the
presettings of the relevant weight class in relation to their weight, be separated
if they are outside the tolerance range, or they may only be checked without being
labeled.
For a tolerance check, the statistics function must be activated as described on
page 3 -- 93. With the statistics function activated, all packages of this weight
class are subjected to a statistical evaluation. The tolerance check is described
on the following pages and also on page 3 -- 89.
The statistical evaluation may be continuously indicated in various display modes
(see description from page 3 -- 82 onward). If it is activated in several weight class
columns, the display of another weight class column may also be selected as des-
cribed on page 3 -- 86.
2.9.2 Labeling
-- Call the PLU data of article (see section 2.1).
-- If necessary call up the weight class parameters manually (see page 2 -- 26).
-- Place the package on the scale.
If scale is stable the respective label is printed automatically
(if ”Autom.” is activated).
-- Remove the package weighed.
-- Place the next package on the scale.
-- Remove the label from the labeler and affix it to the removed
package.
The total display permanently indicates
the number of labeled
packages, as well as their weight total (see page 3 -- 169 for des-
cription).
If required, print total labels (see sec. 3.4)
2
*1: # xx
kg xx,xxx
€ xxx,xx
<=
# xx