Presettings for labeling
Operating instructions GLP
3 -- 23
6.562.98.5.01.18
3.1.4.7 Price-relevant weight: net weight or drained weight
The price is calculated on the basis of the unit price and the net weight as stan-
dard. If an ingredient proportion is preset and the calculated difference is to be
used as the drained weight to calculate the price, a relevant setting may be made
here. The calculated drained weight is then printed out on the label with the text
”Drained weight” in lieu of the net weight (see label example).
Before labeling other articles, set the device back to the operating
mode ”Net”.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Article
data
Weight
[ETC] -- Call up the selection menu.
Price--rel.
weight
Drnd.Net
Select ’Drain.’ if the drained weight is to be used in place of the
net weight to calculate the price.
Standard setting: Net
With ’Drained weight’ selected, the determined
drained weight is printed out on the label
together with the text ’Drained weight’.