Presettings
Operating instructions GLP
3 -- 66
6.562.98.5.01.18
3.5.1.2 Label removal light barrier
The label removal light barrier may be temporarily deactivated
-- to print labels which eject with the backing paper (see page 2 -- 32)
-- for ticket operation
-- if the light barrier is defective
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Labe-
ling
Release
mode
-- Call up the selection menu.
--
+
Lab.rem.
LB
Select ”w/o(--)” if the label removal light barrier is to be deactivated.
Standard setting: with(+)
Switch the light barrier back on after deactivation.
3.5.1.3 Audible signal
The release of an audible signal output after stabilization of scale telling the ope-
rator that a package change has taken place on the scale may be set here.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] 2
Labe-
ling
Release
mode
-- Call up the selection menu.
+--
! Beep !
Select ”with(+)” if the audible signal is to be activated.
Standard setting: without(--)
3.5.1.4 Number of label copies
If packages are labeled manually, the number of label copies desired may be pre-
set here. The preset number of identical labels is then automatically printed for
each article labeled.
Operating sequence: Description
------------------------------------------------------------------------------------------------------------------------------------------------------
[MODE] [2]
Labe-
ling
Release
mode
Nmb.lab.
copies
-- Call up the input menu.
xx [ENTER] , [ETC] -- Enter the new value and acknowledge or save in da-
tabase (see page 1 -- 32).
3